Wire the non-separated conservatory into the §3 heat-transmission +
§1 dimensions cascade per RdSAP 10 §6.1 (PDF p.49) + Table 25 (p.51):
"The floor area and volume of a non-separated conservatory are added to
the total floor area and volume of the dwelling. Its roof area is taken
as its floor area divided by cos(20°), and wall area is taken as the
product of its exposed perimeter and its height. ... The conservatory
walls and roof are taken as fully glazed ... Glazed walls are taken as
windows, glazed roof as rooflight."
New `worksheet/conservatory.py` derives the geometry:
- height from the equivalent storey count (§6.1: 1 storey → ground-floor
room height; 1½ → ground + 0.25 + 0.5×first; etc.);
- glazed WALL → window (27) at Table 25 U (double 3.1 / single 4.8) with
the §3.2 curtain resistance (R=0.04) → U_eff 2.758;
- glazed ROOF → rooflight (27a) at Table 25 roof U (double 3.4 / single
5.3) + curtain → U_eff 2.993;
- FLOOR → (28a) via BS EN ISO 13370 as an uninsulated SOLID ground floor
with 300 mm walls (§5.12, spec p.43), exposed perimeter = glazed
perimeter → U 0.89;
- glazed wall + roof + floor areas join (31)/(36); the fully-glazed
structure walls/roof add nothing (the glazing IS the window/rooflight).
`dimensions_from_cert` adds the conservatory floor area to TFA (4) and
floor area × height to volume (5) (feeds ventilation (8)), without making
it a storey (avg storey height for §2 infiltration is unchanged).
Pinned against the simulated case-44 P960 §3 at abs=1e-4 — every line ref
EXACT: (4) 95.3800, (5) 257.1630, (27) 96.1169, (27a) 38.2201, (28a)
21.4164, (29a) 35.5852, (30) 7.4688, (31) 294.2900, (33) 207.3274,
(36) 23.5432. The remaining whole-dwelling SAP/CO2 gap is the §6 solar
gains, closed in the next slice. Worksheet harness stays 47/47 0-raised.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||
| fixtures | ||
| __init__.py | ||
| test_elmhurst_end_to_end.py | ||
| test_elmhurst_extractor.py | ||
| test_end_to_end.py | ||
| test_extractor.py | ||
| test_heating_systems_corpus.py | ||
| test_pdf.py | ||
| test_room_heater_worksheet_001431.py | ||
| test_summary_pdf_mapper_chain.py | ||