SAP 10.2 Appendix M1 §3a (p.93) defines PV-eligible demand as
D_PV,m = E_L,m + E_A,m + E_cook,m + E_ES,m + (231)·n_m/365 + E_space,m + E_water,m
where E_L,m is the lighting ELECTRICITY (Appendix L eq L10, = line (232)).
The cascade fed `internal_gains_result.lighting_monthly_w` — the L12 internal
heat GAIN G_L,m = E_L,m × 0.85 ("assuming 15%" of lighting energy does not
become internal heat) — into D_PV, understating it by 15% of lighting on
every PV cert. That depressed the monthly β onsite/export split and
under-credited PV primary energy uniformly across the year.
Same gain-vs-electricity class as the cooking fix S0380.73 (L18 gain vs L20
electricity). Fix: scale the (shape-identical) lighting gain profile to the
annual E_L `lighting_kwh_per_yr` (= (232)), mirroring the (219)m hot-water
scale-to-annual. Magnitude-only, so the shape-weighted lighting CO2/PE
effective factor (Σkwh×f/Σkwh, magnitude-invariant) is unchanged; appliances
need no scaling (G_A = E_A, no 0.85). Diagnosis was empirical first (calc
lighting D_PV 95.1 vs worksheet (232) 111.88, ratio exactly 0.85) then
confirmed against the spec text (L9d/L10/L12, M1 §3a).
Impact (calc − full-precision dr87 worksheet): ALL 47 worksheet certs now
match at <1e-4 on BOTH PE (max |Δ| 0.0000 kWh/m²) and CO2 (max |Δ| 0.0000 kg)
— the convergence target, met cohort-wide. Combined with S0380.187 this
closes the entire gas+PV + ASHP PV residual. Re-pinned 47 worksheet residuals
to 0.0000 and 31 drifted lodged residuals (PV certs). SAP integers unchanged;
chain SAP 1e-4 intact (164 pass). 2273 pass, 0 regressions; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||