A mid-/top-floor flat whose lowest floor is lodged as an exposed floor
(API floor_heat_loss=1) had its floor area zeroed by the dwelling-level
exposure heuristic, which keys only on the flat label and defaults
has_exposed_floor=False (assuming the floor sits over another *heated*
dwelling). RdSAP 10 §3.12 (PDF p.25) is explicit:
"Otherwise the floor area of the flat ... is:
- an exposed floor if there is an open space below"
i.e. a flat cantilevered over a passageway IS a heat-loss floor on
Table 20. The per-BP `is_exposed_floor` lodgement is authoritative and
now overrides the dwelling-level suppression upward, mirroring the
existing "another dwelling below" party override (which suppresses
downward). The code-1↔"E To external air" enum is confirmed by the
paired API+Summary worksheet certs (0350, 3800).
Eval: 45.1% → 45.3% within 0.5 (909 computed); cert 3836 +6.79 → +0.77,
5717 +1.31 → -0.07 and 0997 +0.76 → +0.05 cross into <0.5. Two
already-failing under-rated certs (7636, 2241) shift further — both are
dominated by independent cost-side over-counts the exposed floor merely
unmasks (7636 walls = 8.98 W/K for 33.87 m² is the real defect).