Model/backend/documents_parser
Khalim Conn-Kowlessar ca27f0b9d8 Charge an oil storage-combi its PCDB internal-store water-heating loss 🟩
An oil STORAGE combi (Worcester Greenstar Heatslave II, PCDB 18415,
store_type 1) zeroed its internal-store loss: pcdb_combi_loss_override
defers on store_type in {1,2,3} and a combi has no cylinder, so line
(56) dropped to zero — under-costing hot water and over-rating SAP by
+2.0..+4.9 across the five LRHA WAVE 3 oil combis.

SAP 10.2 Table 2 note b) now includes the store loss when the combi's
efficiency is from the PCDB: the PCDB store volume (field 42) and
insulation thickness (field 44) feed Table 2/2a with the Table 2b
storage-combi temperature factor, reproducing the accredited Elmhurst
P960 worksheet exactly (5.4175 kWh/day, Jan 167.94, ~1977 kWh/yr).

Cohort: within-0.5 55.3% -> 58.3%, MAE 0.675 -> 0.531; ratchet
tightened accordingly.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-27 12:43:52 +00:00
..
handler address JTK review comments 2026-04-20 15:11:17 +00:00
tests Charge an oil storage-combi its PCDB internal-store water-heating loss 🟩 2026-07-27 12:43:52 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
db_writer.py include updating epc_property_data to pashub to ara workflow 2026-04-29 09:55:14 +00:00
elmhurst_extractor.py fix(ventilation): read Blower Door AP50 pressure test (Summary) 2026-06-16 23:18:17 +00:00
extractor.py Model a PasHub dwelling's second main heating system 🟩 2026-07-24 15:45:47 +00:00
local_runner.py update local runner to work for elmhurst 2026-04-24 14:01:36 +00:00
parser.py Persist resolved UPRN on PasHub site-notes rows (#1537) 2026-07-10 13:19:28 +00:00
pdf.py update local runner to work for elmhurst 2026-04-24 14:01:36 +00:00