Task 9d271e98-96e6-4be6-bb50-e9be6f954003 (portfolio 796) failed 21
"Top-floor flat" properties with "EnergyElement: missing required
field 'description'". Every one lodges a second walls[] entry that is
a bare zero-rated party-wall boundary element
({"energy_efficiency_rating": 0, "environmental_efficiency_rating": 0},
no description key at all) — unlike the sibling floors/roofs
"(other premises above/below)" sentinel convention, which does carry
text. Confirmed schema-wide across all 21 failing certs.
Default description to "" rather than fabricate construction text:
_joined_descriptions (heat_transmission.py) already filters out falsy
descriptions, so this is calc-neutral — it only unblocks the parse.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||