Model/datatypes
Khalim Conn-Kowlessar 81392208c4 Slice 41: schema-21.0.1 ventilation completeness — 7 vent / draught fields plumbed
Audit of raw-JSON keys vs RdSapSchema21_0_1 across the 9-fixture
golden cohort surfaced 7 vent / draught fields silently dropped at
deserialization: blocked_chimneys_count, open_flues_count,
closed_flues_count, boilers_flues_count, other_flues_count, psv_count,
has_draught_lobby. cert_to_inputs reads all of them for the §2
infiltration cascade; without them the calc treats every dwelling as
flue-free / vent-free / no draught lobby and under-counts ACH.

Fix: declare the 7 fields on RdSapSchema21_0_1; extend the mapper to
surface blocked_chimneys_count on EpcPropertyData top-level (already
declared) and the other 6 on SapVentilation (extends the slice 37
extract_fans_count work). has_draught_lobby coerces "true"/"false"
strings to bool to match the SapVentilation type.

Cohort residual shifts after re-pinning:
- LN12 (0390-2254) — SAP +1 → 0 (FIRST CERT TO HIT LODGED SAP EXACTLY).
  blocked_chimneys=2 reduces infiltration, tightens both SAP and PE
  (PE −10.62 → −3.14, CO2 −0.11 → +0.04).
- 0300 — PE +18.92 → +17.34, CO2 −0.43 → −0.54 (open_flues=1 +
  has_draught_lobby=true cross-cancel near-zero).
- 0390-2954 — PE −25.62 → −27.64, CO2 −2.45 → −2.58 (has_draught_lobby=true).
- 8135 — PE −17.58 → −14.37, CO2 −0.22 → −0.15 (blocked_chimneys=1).
- Other 5 fixtures (0240, DE22, 6035, 7536, plus retired 9390): no shift
  — their certs lodge zeros or no vent fields beyond what Slice 37 plumbed.

Rounded-SAP cohort distribution post-slice:
  0 (LN12), +1 (8135), +2 (9390), +3 (7536), +8 (DE22, spec-drift),
  -6 (6035), -7 (0390-2954), -9 (0300), -12 (0240, RR-driven).

Schema scope: 21.0.1 only. 21.0.0 schema's SapBuildingPart shares the
same mapper code but no 21.0.0 fixtures live in the cohort to anchor
against; defer to a future slice if needed.

930/930 Elmhurst cascade green. 14/14 golden cohort green at new
pinned residuals. 77/77 mapper tests green. Pyright net-zero (34
errors before and after).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-05-24 14:27:32 +00:00
..
epc Slice 41: schema-21.0.1 ventilation completeness — 7 vent / draught fields plumbed 2026-05-24 14:27:32 +00:00
magicplan typing and renaming 🟪 2026-05-07 13:26:49 +00:00
__init__.py further breaking up code 2023-07-20 12:24:34 +01:00
datatypes.py further breaking up code 2023-07-20 12:24:34 +01:00
enums.py completed build of new demo portfolio - some fixed required still 2023-11-20 14:42:16 +00:00