Closes the cert 0330 API path Layer 4 gate (Δ -0.000011 vs worksheet
SAP 61.5993) by surfacing two previously-broken inputs to the HW
cascade plus aligning the wall-net-deduction with the worksheet's
2-d.p.-per-window rounding convention.
(a) RdSAP schema 21.0.x `shower_outlets` shape mismatch:
real-API certs lodge `[{"shower_outlet_type": N, "shower_wwhrs":
M}, ...]` (a list of bare ShowerOutlet dicts), but the schema
modelled it as `[ShowerOutlets]` with nested
`{"shower_outlet": {...}}` wrappers. `from_dict` silently dropped
every bare element's payload (left `shower_outlet=None`),
blanking the cascade's mixer/electric counts on cert 0330 (and 4
other golden fixtures). Normalisation in `from_api_response`
rewrites the bare list shape to the wrapped form before
`from_dict` parses, so the schema's `ShowerOutlets` dataclass
sees the data it expects — no schema-class breakage downstream.
New helper `_count_shower_outlets_by_type` walks the normalised
list and counts outlets by integer code:
- code 1 → mixer (drives `mixer_shower_count`)
- code 2 → electric (drives `electric_shower_count`)
Empirically derived from the golden cohort + Summary mapper
cross-check (cert 0330 lodges code 2 + Summary surfaces "Electric
shower"; cert 0240 lodges multiple code-1 outlets on a
conventional oil-boiler + cylinder dwelling). No spec page
reference found.
Wired into both `from_rdsap_schema_21_0_0` and
`from_rdsap_schema_21_0_1`. Effect on cert 0330 API path:
`mixer_shower_count` 1 (cascade default) → 0; `electric_shower_
count` None (= 0) → 1; HW kWh 3172.65 → 2111.93. SAP Δ +2.1155
→ -0.0012.
(b) Per-window 2-d.p. area rounding in wall-net deduction:
RdSAP 10 §15 rounds per-window area at 2 d.p. before any sum.
The cascade's `windows_w_per_k_total` branch already rounds
per-window for the curtain transform; the wall-net deduction
branch (computing `gross_wall - windows - door` for the (29a)
line) was rounding the SUM once, which for cert 0330's 9 Main
windows yields 12.22 m² vs the worksheet's per-window-rounded
12.23 m² — Δ +0.01 m² × U=1.5 = +0.015 W/K on (29a). Aligned
both branches to round per-window, matching worksheet line (27).
SAP Δ -0.0012 → -0.000011.
Layer 4 chain test added:
- `test_api_0330_full_chain_sap_matches_worksheet_pdf_exactly` pins
cert 0330 API path SAP at 1e-4 vs worksheet 61.5993. This is the
second boiler validation cert with a Layer 4 1e-4 gate (cert
001479 is the first).
Re-pinned golden cert residuals (shifted by changes (a) and (b)):
- 0300: PE +7.52 → +8.44, CO2 -0.27 → -0.23 (Slice 98a — electric
shower count surfaced; cert has 1 electric + 1 mixer outlets)
- 2130: PE -38.17 → -38.18, CO2 +0.305 → +0.304 (Slice 98b —
window rounding edge)
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||
| handler | ||
| tests | ||
| __init__.py | ||
| db_writer.py | ||
| elmhurst_extractor.py | ||
| extractor.py | ||
| local_runner.py | ||
| parser.py | ||
| pdf.py | ||