Khalim Conn-Kowlessar 2b1afa7339 S0380.204: extract Main Heating2's own emitter + control (§14.1)
Prerequisite for the SAP 10.2 p.186 two-systems-different-parts MIT.
When two main systems heat different parts of a dwelling, §14.1 Main
Heating2 lodges its OWN "Heat Emitter" + "Main Heating Controls Sap"
(simulated case 6: Main 1 radiators / control 2106 serving the living
area, Main 2 underfloor / control 2110 serving elsewhere). The extractor
+ mapper dropped both — `MainHeatingDetail.heat_emitter_type` and
`main_heating_control` came through as empty-string sentinels, so the
cascade saw system 2 as having no responsiveness (defaulted R=1.0) and no
control type.

- `MainHeating2` datatype gains `heat_emitter` + `heating_controls_sap`.
- The extractor reads them from the §14.1 block.
- `_map_elmhurst_main_heating_2` maps them via the same helpers as Main 1
  (`_elmhurst_heat_emitter_int` → underfloor-in-screed = emitter 2, Table
  4d R=0.75; `_elmhurst_sap_control_code` → 2110, Table 4e type 3),
  threading the dwelling floor + age band for the underfloor subtype.

Empty-string fallback preserved for the legacy DHW-only Main 2 (cert
000565 §14.1 omits emitter/control). No cascade output changes yet — the
MIT consumer lands in S0380.205. Full suite 2358 pass + 0 fail.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-03 15:53:32 +00:00
..
epc S0380.204: extract Main Heating2's own emitter + control (§14.1) 2026-06-03 15:53:32 +00:00
magicplan typing and renaming 🟪 2026-05-07 13:26:49 +00:00
__init__.py further breaking up code 2023-07-20 12:24:34 +01:00
datatypes.py further breaking up code 2023-07-20 12:24:34 +01:00
enums.py completed build of new demo portfolio - some fixed required still 2023-11-20 14:42:16 +00:00