Khalim Conn-Kowlessar 8452cf9e2d S0380.180: heat-network distribution pumping electricity (§C3.2) — closes CH1
SAP 10.2 Appendix C §C3.2 (PDF p.51), verbatim: "CO2 emissions and
Primary Energy associated with the electricity used for pumping water
through the distribution system are allowed for by adding electrical
energy equal to 1% of the energy required for space and water heating."

Worksheet line (313) = 0.01 × [(307)+(310)]; its CO2 (372) and PE (472)
bill on the Table 12d/12e monthly factors for fuel code 50 ("electricity
for pumping in distribution network"), weighted by the monthly heat
profile per worksheet footnote (a). (307)m/(310)m = (space_demand +
hw_output) / efficiency (the cascade models a heat network's generator
efficiency as 1/DLF).

This un-defers the (372)/(472) front the post-S0380.179 handover flagged
"don't guess until the factor source is identified": the source is
§C3.2 + Table 12d/12e code 50, NOT an empirical constant. The apparent
0.1994/0.2114 "factor" is an Elmhurst DISPLAY artifact — the worksheet
shows the (372) energy column as 0.01×(307) (space only) while computing
emissions on 0.01×(307+310) per the §C3.2 text. Verified EXACT line-by-
line against the CH2 corpus worksheet: (372)=23.6007 CO2 (rating),
(472)=208.2267 PE (demand).

New `_heat_network_distribution_electricity` helper (gated on
`_is_heat_network_main`) precomputes the energy + effective CO2/PE
factors; three new CalculatorInputs fields + calculator.py CO2/PE
summation terms (0.0/None → no-op for individually-heated certs).

Closures:
  CH1 (Boilers/Gas)  CO2 −23.60→−0.00, PE −208.23→+0.00  — FULLY EXACT
  CH3 (HP/Elec)      CO2 −98.92→−75.32, PE −457.54→−249.32 (distribution
                     component closed; code-304 community-HP COP remains)
  CH2/CH4/CH6        gain their (372)/(472) component (CO2 +23.6, PE
                     +208.2); dominant CHP displaced-electricity credit
                     residual (Table 12f + block 12b/13b) is next slice.

No regression on the other 36 corpus variants (helper returns None off
heat-network mains) + golden + U985 fixtures. 2223 pass + 1 skip + 0
fail; pyright net-zero 43→43.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-02 18:04:16 +00:00
..
applications refactor(ara): rename FirstRunPipeline → AraFirstRunPipeline (PR #1139 review) 2026-06-01 15:00:33 +00:00
domain S0380.180: heat-network distribution pumping electricity (§C3.2) — closes CH1 2026-06-02 18:04:16 +00:00
infrastructure Remove EPC and asset_list changes unrelated to SAL handler 2026-06-01 16:39:09 +00:00
orchestration Merge branch 'main' of https://github.com/Hestia-Homes/Model into feature/per-cert-mapper-validation 2026-06-02 16:10:41 +00:00
repositories Merge branch 'main' of https://github.com/Hestia-Homes/Model into feature/per-cert-mapper-validation 2026-06-02 16:10:41 +00:00
utilities tests framework completed 2026-05-20 14:00:19 +00:00
__init__.py added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
conftest.py tests framework completed 2026-05-20 14:00:19 +00:00
test_lambda_packaging.py more tests to ensure we don't deploy something that is brokern 2026-06-02 15:03:20 +00:00