Model/backend/documents_parser/tests/fixtures
Khalim Conn-Kowlessar 1f8a070f66 Slice S0380.19: count Elmhurst shower outlets by type (no more hardcoded 1)
Surfaces the lodged shower multiplicity from the Elmhurst Summary §16
on the EPC. Previously `_map_elmhurst_sap_heating` hardcoded:

  electric_shower_count = 1 if has_electric_shower else None
  mixer_shower_count    = 0 if has_electric_shower else None

losing the count for any cert with ≥ 2 outlets. Cert
7800-1501-0922-7127-3563 lodges TWO instantaneous electric showers
("Shower 01" + "Shower 11") but the mapper produced
`electric_shower_count=1`. After this slice:

  electric_shower_count = Σ(s for s in showers if s.outlet_type
                              == "Electric shower")
  mixer_shower_count    = Σ(s for s in showers if s.outlet_type
                              != "Electric shower")

**Cascade SAP effect:** None on cert 7800. Appendix J's eq J16
(`N_ES,per_outlet = N_shower / N_outlets`) and eq J18 (Σ_j E_ES,j)
are symmetric in N_electric_showers when there are no mixer outlets,
so the lodged (64a) kWh and (247a) cost are unchanged. The fix is
correctness-by-construction, not a delta-closer for the negative-band
certs (their +0.69 GBP total-cost gap traces to the gas hot-water
kWh path — separate slice).

**Hand-built fixture updates (5):** the cohort-1 hand-builts at
`domain/sap10_calculator/worksheet/tests/_elmhurst_worksheet_*.py`
previously omitted `electric_shower_count` / `mixer_shower_count`
(implicitly None), which matched the mapper's pre-slice None
sentinel. Updated each to the lodged counts the mapper now surfaces:
  000474: 1 mixer  → (0, 1)
  000477: 1 mixer  → (0, 1)
  000480: 1 mixer  → (0, 1)
  000490: 1 mixer  → (0, 1)
  000516: 1 mixer  → (0, 1)
000487 (already at (1, 0) for an electric-shower lodging) unchanged.

Tests:
- `test_summary_7800_two_electric_showers_count_as_two_not_one` —
  pins the multi-shower mapping for cert 7800 (Summary_000890.pdf).
- 5 hand-built field-parity tests
  (`test_from_elmhurst_site_notes_matches_hand_built_*`) now pass at
  the new integer counts instead of None.

Pyright net-zero per file:
- datatypes/epc/domain/mapper.py: 32 (baseline 32)
- backend/documents_parser/tests/test_summary_pdf_mapper_chain.py: 0

Regression baseline: 699 pass + 10 fail (= prior 698 + 10 + 1 new).

Spec refs:
- SAP 10.2 Appendix J §1a — outlet counting drives `N_outlets` used
  in eq J6/J7 (mixer shower water draw) and eq J16/J17/J18 (electric
  shower energy).
- Cert 7800-1501-0922-7127-3563 Summary §16 "Showers" lodgement.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-05-28 07:16:32 +00:00
..
elmhurst_site_notes_1_text.json elmhurst site notes fixture 2026-04-24 13:09:30 +00:00
elmhurst_site_notes_2_text.json extract window frame details from elmhurst site notes 🟥 2026-04-27 15:50:25 +00:00
ElmhurstSiteNotes.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
ElmhurstSiteNotes_2.pdf extract window frame details from elmhurst site notes 🟥 2026-04-27 15:50:25 +00:00
pashub_site_notes_1_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_2_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_3_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_4_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_5_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_6_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_7_text.json Extract address when Property photo element is missing from PDF 🟩 2026-04-30 16:25:41 +00:00
PasHubSiteNotes_1.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_2.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_3.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_4.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_5.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_6.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_7.pdf Extract address when Property photo element is missing from PDF 🟩 2026-04-30 16:25:41 +00:00
Summary_000474.pdf Scaffold: end-to-end Summary→EpcPropertyData chain test for 000474 (xfail) 2026-05-24 17:40:06 +00:00
Summary_000477.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000480.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000487.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000490.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000516.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000784.pdf chore: stage cert 9501 fixtures (second boiler validation cert) 2026-05-26 18:53:08 +00:00
Summary_000884.pdf Slice S0380.16: add 'Normal' → cylinder_size=2 (110 L) for cohort 2 2026-05-27 22:44:02 +00:00
Summary_000888.pdf Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
Summary_000889.pdf Slice S0380.16: add 'Normal' → cylinder_size=2 (110 L) for cohort 2 2026-05-27 22:44:02 +00:00
Summary_000890.pdf Slice S0380.19: count Elmhurst shower outlets by type (no more hardcoded 1) 2026-05-28 07:16:32 +00:00
Summary_000897.pdf chore: stage cert 0330 fixtures (boiler pilot) 2026-05-26 17:37:14 +00:00
Summary_000898.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000899.pdf chore: stage cert 0380 fixtures (HP pilot — deferred workstream) 2026-05-26 17:37:34 +00:00
Summary_000900.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000901.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000902.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000903.pdf Slice S0380.9: multi-array PV support + close cert 0350 to ASHP spec floor 2026-05-27 20:44:13 +00:00
Summary_000904.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000910.pdf Slice S0380.18: u_party_wall flat default per RdSAP10 Table 15 footnote* 2026-05-27 23:24:58 +00:00
Summary_001479.pdf Slice 54: Elmhurst mapper sets extensions_count from len(survey.extensions) 2026-05-24 22:15:47 +00:00