Model/backend/documents_parser/tests/test_summary_pdf_mapper_chain.py
Khalim Conn-Kowlessar f502db8c74 Slice 95: API mapper TFA from per-bp dims + window area 2dp rounding — cert 001479 to 1e-4
The end-to-end production cascade `from_api_response → cert_to_inputs →
calculate_sap_from_inputs` now hits cert 001479's worksheet continuous
SAP 69.0094 at abs < 1e-4 (was +0.000584). Two fixes:

1. API mapper: `from_rdsap_schema_21_0_{0,1}` computes `total_floor_
   area_m2` as Σ per-bp `sap_floor_dimensions[*].total_floor_area.value`
   (cert 001479: 30.45+30.77+5.37+1.92 = 68.51), not the lodged scalar
   (rounded integer 69). `water_heating_from_cert` reads `epc.total_
   floor_area_m2` directly for occupancy N (Appendix J), which propagates
   to HW kWh (+6.31 → ~0), Appendix L lighting (+0.98 → 0), and internal
   gains (+25.72 W·months → 0).

2. Cascade window area rounding per RdSAP 10 §15 "Rounding of data"
   (p.66): "All element areas (gross) including window areas: 2 d.p."
   `solar_gains.py` and `internal_gains.py` now round `w * h` to 2 d.p.
   to match the existing `heat_transmission.py` pattern (line 344).
   Closes the residual solar gains delta (+1.50 W·months → 0) that
   became dominant once TFA was fixed.

Re-pinned 5 golden cert residuals where TFA + area rounding shifted
output: 0240 (SAP -14→-15, PE +14.6650→+17.8450, CO2 +0.8060→+1.0097),
6035 (PE +48.2971→+49.5139, CO2 +1.1016→+1.1423), 8135 (PE -2.4194→
-2.4072, CO2 -0.0198→-0.0195), 2130 (PE -38.1521→-38.1666), 0390
(PE +1.6837→+1.6962, CO2 +0.0637→+0.0639).

New test: `test_api_001479_full_chain_sap_matches_worksheet_pdf_
exactly` formalises Layer 4 of the validation stack as a 1e-4 gate.

Pyright net-zero (mapper.py 33).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-05-26 09:30:41 +00:00

760 lines
32 KiB
Python

"""End-to-end validation for the Elmhurst Summary→EpcPropertyData chain.
The 6 Elmhurst worksheet fixtures in `domain.sap.worksheet.tests`
build their `EpcPropertyData` synthetically — they validate the
calculator + cascade in isolation from the mapper. This file pins
the OTHER half of the chain: `from_elmhurst_site_notes` must produce
a calculator-equivalent `EpcPropertyData` when fed the Summary PDF
the worksheet was generated from. Together with the worksheet
cascade tests, this closes the loop: extractor + mapper + cascade
+ calculator validated end-to-end against the authoritative
Elmhurst documents.
Status: GREEN. For cert U985-0001-000474, this pipeline produces an
unrounded SAP within 0.5 of the worksheet PDF's `62.2584` (line 257).
The cascade itself reproduces Elmhurst's calculator exactly on
hand-built inputs (handbuilt → 62.2584 to 4 d.p.); the remaining
sub-half-point gap from the mapped path is non-load-bearing field
drift (e.g. central_heating_pump_age the Summary PDF doesn't lodge).
Preprocessing: the existing `ElmhurstSiteNotesExtractor` was written
against Textract-style output (label\\nvalue pairs in spatial
reading order). We don't have Textract in the test environment, so
this helper converts `pdftotext -layout` output (label-whitespace-
value on a single line) into the Textract-style sequence the
extractor expects. Test-only preprocessing; production runs through
Textract directly.
"""
from __future__ import annotations
import dataclasses
import json
import re
import subprocess
from pathlib import Path
from typing import cast
from backend.documents_parser.elmhurst_extractor import ElmhurstSiteNotesExtractor
from datatypes.epc.domain.mapper import EpcPropertyDataMapper
from domain.sap.calculator import calculate_sap_from_inputs
from domain.sap.rdsap.cert_to_inputs import SAP_10_2_SPEC_PRICES, cert_to_inputs
from domain.sap.worksheet.tests import (
_elmhurst_worksheet_000474 as _w000474,
_elmhurst_worksheet_000477 as _w000477,
_elmhurst_worksheet_000480 as _w000480,
_elmhurst_worksheet_000487 as _w000487,
_elmhurst_worksheet_000490 as _w000490,
_elmhurst_worksheet_000516 as _w000516,
)
_FIXTURES = Path(__file__).parent / "fixtures"
_SUMMARY_000474_PDF = _FIXTURES / "Summary_000474.pdf"
_SUMMARY_000477_PDF = _FIXTURES / "Summary_000477.pdf"
_SUMMARY_000480_PDF = _FIXTURES / "Summary_000480.pdf"
_SUMMARY_000487_PDF = _FIXTURES / "Summary_000487.pdf"
_SUMMARY_000490_PDF = _FIXTURES / "Summary_000490.pdf"
_SUMMARY_000516_PDF = _FIXTURES / "Summary_000516.pdf"
_SUMMARY_001479_PDF = _FIXTURES / "Summary_001479.pdf"
# GOV.UK EPB API JSON for cert 001479 — the API-path counterpart of the
# Summary_001479.pdf fixture. Together they drive the API ≡ Summary
# parity workstream; Layer 4 of the validation stack is "API cascade SAP
# matches worksheet continuous SAP at 1e-4".
_API_001479_JSON = (
Path(__file__).parents[3]
/ "packages/domain/src/domain/sap/rdsap/tests/fixtures/golden"
/ "0535-9020-6509-0821-6222.json"
)
def _summary_pdf_to_textract_style_pages(pdf_path: Path) -> list[str]:
"""Convert a Summary PDF into the per-page text format the existing
`ElmhurstSiteNotesExtractor` expects (label\\nvalue sequences).
`pdftotext -layout` preserves the spatial pairing of label and value
on each line; we split each line on 2+ spaces to surface the
label/value tokens, then concatenate them back into a single
newline-delimited stream per page.
"""
info = subprocess.run(
["pdfinfo", str(pdf_path)], capture_output=True, text=True, check=True
).stdout
m = re.search(r"Pages:\s+(\d+)", info)
if m is None:
raise RuntimeError(f"Could not parse page count from {pdf_path}")
page_count = int(m.group(1))
pages: list[str] = []
for i in range(1, page_count + 1):
layout = subprocess.run(
[
"pdftotext", "-layout", "-f", str(i), "-l", str(i),
str(pdf_path), "-",
],
capture_output=True, text=True, check=True,
).stdout
tokens: list[str] = []
for line in layout.splitlines():
if not line.strip():
tokens.append("")
continue
parts = [p for p in re.split(r"\s{2,}", line.strip()) if p]
tokens.extend(parts)
pages.append("\n".join(tokens))
return pages
def test_summary_000474_mapper_produces_three_building_parts() -> None:
# Arrange — cert U985-0001-000474 is a mid-terrace with 3 building
# parts (Main + 2 extensions) per the hand-built worksheet fixture
# at packages/domain/src/domain/sap/worksheet/tests/
# _elmhurst_worksheet_000474.py. Routing the Summary PDF through
# extractor + mapper must yield the same count.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000474_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
# Act
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Assert
assert len(epc.sap_building_parts) == 3
def test_summary_000474_mapper_extracts_seven_windows() -> None:
# Arrange — cert U985-0001-000474's §11 table lodges 7 windows
# across Main + 1st Extension + 2nd Extension. The legacy Textract-
# style window parser couldn't anchor on the Summary PDF's tabular
# layout; the new W/H/Area-plus-Manufacturer anchor pair picks them
# all up.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000474_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
# Act
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Assert
assert len(epc.sap_windows) == 7
def test_summary_000474_full_chain_sap_matches_worksheet_pdf_exactly() -> None:
# Arrange — the full Summary→ElmhurstSiteNotes→EpcPropertyData→cascade
# →SAP path against the U985-0001-000474 worksheet PDF's unrounded
# SAP rating (line 257: SAP value 62.2584, rating (258) = 62).
# Because the Summary PDF carries the same source-of-truth data that
# the hand-built worksheet fixture encodes by hand, and because the
# cascade matches Elmhurst's calculator to 4 d.p. on those hand-
# built inputs, this end-to-end path MUST produce the same unrounded
# SAP value. Any non-trivial drift = a real mapper bug dropping
# information from the Summary PDF.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000474_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Act
result = calculate_sap_from_inputs(
cert_to_inputs(epc, prices=SAP_10_2_SPEC_PRICES)
)
# Assert — within the same 1e-4 tolerance the other Elmhurst worksheet
# tests pin against. 0.5 is the API-cert residual tolerance (the API
# publishes rounded SAP integers, so up to half a SAP point is just
# rounding); for Elmhurst worksheet inputs the cascade reproduces
# Elmhurst exactly and we expect identical outputs.
worksheet_unrounded_sap = 62.2584
assert abs(result.sap_score_continuous - worksheet_unrounded_sap) < 1e-4
def test_summary_000477_full_chain_sap_matches_worksheet_pdf_exactly() -> None:
# Arrange — cert U985-0001-000477 is a single-bp mid-terrace with
# a 15.06 m² Room-in-Roof storey and zero baths lodged. Worksheet
# PDF lodges unrounded SAP 65.0057. Drives the chain through the
# `RoomInRoof.detailed_surfaces` cascade with stud walls @ 100mm
# Mineral, two uninsulated slopes, two party gable walls, plus the
# RR/storey-area suspended-timber-floor heuristic (RIR < storey →
# 0.2 ACH floor infiltration).
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000477_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Act
result = calculate_sap_from_inputs(
cert_to_inputs(epc, prices=SAP_10_2_SPEC_PRICES)
)
# Assert
worksheet_unrounded_sap = 65.0057
assert abs(result.sap_score_continuous - worksheet_unrounded_sap) < 1e-4
def test_summary_000480_full_chain_sap_matches_worksheet_pdf_exactly() -> None:
# Arrange — cert U985-0001-000480 is a mid-terrace with main + one
# extension and a 19.83 m² room-in-roof storey. Worksheet PDF lodges
# unrounded SAP 61.2986 on line "SAP value". The Detailed §3.10 RR
# surfaces (2 stud walls @ 0mm + 2 slopes @ 0mm + 1 flat ceiling @
# 0mm + 2 party gables) plus zero baths drive the chain to 1e-4.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000480_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Act
result = calculate_sap_from_inputs(
cert_to_inputs(epc, prices=SAP_10_2_SPEC_PRICES)
)
# Assert
worksheet_unrounded_sap = 61.2986
assert abs(result.sap_score_continuous - worksheet_unrounded_sap) < 1e-4
def test_summary_000487_full_chain_sap_matches_worksheet_pdf_exactly() -> None:
# Arrange — cert U985-0001-000487 is an enclosed-mid-terrace with
# main bp + 1st extension, a 21.03 m² Room-in-Roof, an electric
# shower, and a 1.43 m² Timber Frame alternative wall on the
# extension. Worksheet PDF lodges unrounded SAP 61.6431. The mapped
# chain has to thread the alt-wall U-value cascade (Thickness
# Unknown → cascade falls back to age-band default U=1.9 for thin
# timber walls) plus the §11 layout variant where the frame_factor
# appears unprefixed on its own line (no "PVC"/"Wood" frame_type).
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000487_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Act
result = calculate_sap_from_inputs(
cert_to_inputs(epc, prices=SAP_10_2_SPEC_PRICES)
)
# Assert
worksheet_unrounded_sap = 61.6431
assert abs(result.sap_score_continuous - worksheet_unrounded_sap) < 1e-4
def test_summary_000516_full_chain_sap_matches_worksheet_pdf_exactly() -> None:
# Arrange — cert U985-0001-000516 is a mid-terrace with main bp +
# 19.02 m² room-in-roof. Worksheet PDF lodges unrounded SAP 62.7937.
# The §11 table mixes 5 vertical windows (U=2.80) with 1 roof
# window (U=3.10 in cert, U=3.40 Table 24 raw); the mapper
# discriminates by `U > 3.0` and routes the high-U entry to
# `sap_roof_windows` so its solar gains feed §6 with the right
# pitch (45°) and Table-24 U-value.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000516_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Act
result = calculate_sap_from_inputs(
cert_to_inputs(epc, prices=SAP_10_2_SPEC_PRICES)
)
# Assert
worksheet_unrounded_sap = 62.7937
assert abs(result.sap_score_continuous - worksheet_unrounded_sap) < 1e-4
def test_summary_000490_full_chain_sap_matches_worksheet_pdf_exactly() -> None:
# Arrange — cert U985-0001-000490 is an end-terrace with main +
# 1st extension. The worksheet PDF lodges unrounded SAP 57.3979.
# End-terrace built-form drives sheltered_sides=1 (RdSAP §S5) and
# the cert's Summary §14.1 Main Heating2 sub-section carries a
# secondary heating SAP code (691, electric panel) — both required
# for the mapped chain to reproduce the worksheet to 1e-4.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000490_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Act
result = calculate_sap_from_inputs(
cert_to_inputs(epc, prices=SAP_10_2_SPEC_PRICES)
)
# Assert
worksheet_unrounded_sap = 57.3979
assert abs(result.sap_score_continuous - worksheet_unrounded_sap) < 1e-4
def test_summary_001479_mapper_extensions_count_matches_extension_bps() -> None:
# Arrange — cert 0535-9020-6509-0821-6222 (Summary_001479) is the first
# cohort cert with an actual GOV.UK API counterpart. Worksheet PDF
# lodges Main + Extension 1 + Extension 2 (3 building parts, 2
# extensions). Pre-slice the Elmhurst mapper hard-coded
# `extensions_count=0` regardless of survey.extensions; this asserts
# the count flows through.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_001479_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
# Act
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Assert
assert epc.extensions_count == 2
assert len(epc.sap_building_parts) == 3
def test_summary_001479_main_party_wall_construction_is_cavity_unfilled() -> None:
# Arrange — cert 001479 Main §7 Walls lodges "Party Wall Type: CU
# Cavity masonry unfilled". The Elmhurst leading-code map previously
# only knew "S" and "C"; "CU" fell through to None, which made the
# cascade default to U=0.25 instead of the worksheet's lodged U=0.50.
# The fix adds "CU" → SAP10 wall_construction code 4 (WALL_CAVITY),
# which `u_party_wall` resolves to U=0.50 — matching the worksheet's
# §3 `Party walls Main … 0.50` row.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_001479_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
# Act
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Assert
assert epc.sap_building_parts[0].party_wall_construction == 4
def test_summary_001479_ext2_floor_is_exposed_to_external_air() -> None:
# Arrange — cert 001479 Ext2 §9 lodges "Location: E To external air"
# — a cantilevered exposed timber floor (the upper-storey extension
# over the back garden). The worksheet's §3 row `Exposed floor Ext2
# … 1.92, 1.20, 1.20` pins this as U=1.20 via Table 20. Pre-slice the
# mapper only routed "U Above unheated space" through `is_exposed_
# floor=True`; "E To external air" fell through to the BS EN ISO
# 13370 ground-floor cascade, dropping the lodged exposure entirely.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_001479_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
# Act
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Assert
ext2 = epc.sap_building_parts[2]
assert ext2.floor_type == "To external air"
assert ext2.sap_floor_dimensions[0].is_exposed_floor is True
def test_summary_001479_ext2_sloping_ceiling_roof_uninsulated_for_pre_1950() -> None:
# Arrange — cert 001479 Ext2 §8 lodges "Type: PS Pitched, sloping
# ceiling" + "Insulation Thickness: As Built" + age band C (1930-49).
# Original 1930s construction had no sloping-ceiling insulation;
# worksheet §3 `External roof Ext2 … 2.30` pins U=2.30 (uninsulated
# Table 16 row 0). Pre-slice the mapper passed thickness=None through,
# routing to `u_roof`'s pitched-roof Table 18 col 1 default (0.40 for
# age C, assumes loft-joist retrofit) — wrong geometry for PS.
# Ext1's PS roof at age M leaves thickness=None (modern build,
# cascade default U=0.15 matches worksheet).
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_001479_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
# Act
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Assert
assert epc.sap_building_parts[2].roof_insulation_thickness == 0
assert epc.sap_building_parts[1].roof_insulation_thickness is None
def test_summary_001479_secondary_heating_routes_mains_gas_fuel() -> None:
# Arrange — cert 001479 §14.1 Main Heating2 lodges "Secondary Heating
# Code: SAP code 605, Flush fitting live effect gas fire, sealed to
# chimney". The Summary surfaces only the SAP code (605); the fuel
# type 26 (mains gas) must be derived from the code range so the
# `_fuel_cost` orchestrator's `secondary_high_rate_gbp_per_kwh`
# picks up Table 32's gas tariff (£0.0348/kWh) rather than the
# default standard-electricity tariff (£0.132/kWh). Worksheet line
# (242) "Space heating - secondary … 3.4800 70.5022" confirms gas
# pricing.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_001479_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
# Act
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Assert
assert epc.sap_heating.secondary_heating_type == 605
assert epc.sap_heating.secondary_fuel_type == 26
def test_summary_001479_full_chain_sap_matches_worksheet_pdf_exactly() -> None:
# Arrange — cert 001479 (Summary_001479.pdf / P960-0001-001479.pdf)
# is the first cohort cert with a real GOV.UK EPB API counterpart
# (cert ref 0535-9020-6509-0821-6222). Worksheet PDF line "SAP value"
# lodges unrounded SAP **69.0094** (rating C 69, also the API-
# published integer). This is the load-bearing forcing function for
# the API↔Elmhurst parity workstream: any drift from 1e-4 means a
# mapper gap, not a calculator bug — the cohort 6 cert cascades all
# reproduce Elmhurst exactly at 1e-4 on hand-built fixtures.
#
# Source-data caveat (documented for future debuggers): Summary §3
# lodges Ext1 age band as "M 2023 onwards"; the worksheet header
# records "Ext1: L". Likely assessor data-entry inconsistency. The
# mapper trusts the Summary (its source of truth); accept whatever
# residual the M vs L disagreement produces.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_001479_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Act
result = calculate_sap_from_inputs(
cert_to_inputs(epc, prices=SAP_10_2_SPEC_PRICES)
)
# Assert — 1e-4 pin, no widening, no xfail (project memory
# `feedback_zero_error_strict`).
worksheet_unrounded_sap = 69.0094
assert abs(result.sap_score_continuous - worksheet_unrounded_sap) < 1e-4
def test_api_001479_full_chain_sap_matches_worksheet_pdf_exactly() -> None:
# Arrange — cert 001479 has both an Elmhurst Summary PDF and a GOV.UK
# EPB API JSON (ref 0535-9020-6509-0821-6222). The Summary cascade
# already pins at worksheet's 69.0094 ± 1e-4 above; this test is the
# Layer 4 production-path gate: API JSON → from_api_response →
# cert_to_inputs → calculate_sap_from_inputs must also hit 69.0094
# at 1e-4. Identical inputs must produce identical outputs; the
# calculator is deterministic, so any drift is a mapper coverage gap.
doc = json.loads(_API_001479_JSON.read_text())
epc = EpcPropertyDataMapper.from_api_response(doc)
# Act
result = calculate_sap_from_inputs(
cert_to_inputs(epc, prices=SAP_10_2_SPEC_PRICES)
)
# Assert — 1e-4 pin against the worksheet's continuous SAP. ±0.5 is
# the API-only fallback (project memory `feedback_api_tolerance_1e_
# minus_4`); when the worksheet is available, identical-inputs-must-
# produce-identical-outputs is the bar.
worksheet_unrounded_sap = 69.0094
assert abs(result.sap_score_continuous - worksheet_unrounded_sap) < 1e-4
# ============================================================================
# Mapper-vs-hand-built EpcPropertyData diff tests
# ============================================================================
# The 6 cohort hand-builts (_elmhurst_worksheet_NNNNNN.build_epc) are the
# 100%-correct calculator-input ground truth — each cascades to its
# worksheet PDF's lodged SAP at 1e-4. The chain tests above only assert
# cascade-output equivalence; the mapper can pass them by producing a
# *different* EpcPropertyData that happens to cascade to the same number.
#
# These tests pin the missing layer: the mapper's EpcPropertyData must
# match the hand-built's load-bearing fields exactly. Every divergence
# surfaced here is a mapper coverage gap to close as its own slice.
#
# "Load-bearing" = the subset of EpcPropertyData fields that drive the
# SAP cascade or carry semantic cross-mapper meaning. Cert-metadata
# fields (address, registration dates, descriptive EnergyElement lists,
# tariff strings) are excluded because they don't change calculator
# output and vary by mapper pathway (the API publishes some, the
# Elmhurst Summary publishes others) without semantic disagreement.
# SapWindow sub-fields the cascade doesn't read (descriptive Union[int,
# str] codes lodged differently by each mapper). The cascade reads
# window_width / window_height / orientation / window_location /
# frame_factor / window_transmission_details.{u_value,solar_
# transmittance} — those WILL still be diffed; everything else on
# SapWindow is metadata and excluded to avoid noise from the int/str
# dual encoding (API mapper produces int codes; Elmhurst mapper
# surfaces the Summary's lodged strings).
_NON_LOAD_BEARING_WINDOW_SUBFIELDS: frozenset[str] = frozenset({
"frame_material",
"glazing_gap",
"window_type",
"glazing_type",
"window_wall_type",
"draught_proofed",
"permanent_shutters_present",
"permanent_shutters_insulated",
})
def _is_excluded_path(path: str) -> bool:
"""Return True for paths the diff should silently skip — non-cascade-
affecting Union[int, str] encoding differences between the API and
Elmhurst mapper outputs that cohort hand-built fixtures don't pin."""
if path.startswith("sap_windows[") and "]." in path:
suffix = path.split("].", 1)[1]
if suffix in _NON_LOAD_BEARING_WINDOW_SUBFIELDS:
return True
if suffix == "window_transmission_details.data_source":
return True
return False
_LOAD_BEARING_FIELDS: tuple[str, ...] = (
# Cascade-driving structural fields
"sap_building_parts",
"sap_windows",
"sap_roof_windows",
"sap_heating",
"sap_ventilation",
"sap_energy_source",
"total_floor_area_m2",
# Building-classification fields driving default cascades
"dwelling_type",
"built_form",
"property_type",
"country_code",
"postcode",
# Counts and openings
"door_count",
"insulated_door_count",
"insulated_door_u_value",
"habitable_rooms_count",
"heated_rooms_count",
"wet_rooms_count",
"extensions_count",
"open_chimneys_count",
"blocked_chimneys_count",
"extract_fans_count",
# Lighting
"cfl_fixed_lighting_bulbs_count",
"led_fixed_lighting_bulbs_count",
"incandescent_fixed_lighting_bulbs_count",
"low_energy_fixed_lighting_bulbs_count",
"fixed_lighting_outlets_count",
"low_energy_fixed_lighting_outlets_count",
# HW / appliances
"solar_water_heating",
"has_hot_water_cylinder",
"has_fixed_air_conditioning",
"has_conservatory",
"has_heated_separate_conservatory",
# Envelope drivers
"percent_draughtproofed",
"mechanical_ventilation",
"pressure_test",
# Construction-detail flags
"addendum",
"lzc_energy_sources",
"any_unheated_rooms",
"number_of_storeys",
"sap_flat_details",
)
def _diff_load_bearing(
mapped: object, hand_built: object, path: str = "",
) -> list[str]:
"""Recursive field diff; yields one line per leaf divergence between
mapped EpcPropertyData and the hand-built fixture. Int/float type
differences with the same numeric value are not flagged.
Strict-pyright posture: arguments typed `object` so each branch
narrows via `isinstance` rather than threading `Any` through the
recursion (which pyright can't reason about under
`strict`/`typeCheckingMode = strict`)."""
out: list[str] = []
if type(mapped) is not type(hand_built):
if not (isinstance(mapped, (int, float)) and isinstance(hand_built, (int, float))):
if not _is_excluded_path(path):
out.append(
f"{path}: TYPE {type(mapped).__name__} vs "
f"{type(hand_built).__name__} mapped={mapped!r} "
f"handbuilt={hand_built!r}"
)
return out
if dataclasses.is_dataclass(mapped) and not isinstance(mapped, type) \
and dataclasses.is_dataclass(hand_built) and not isinstance(hand_built, type):
for fld in dataclasses.fields(mapped):
out.extend(_diff_load_bearing(
getattr(mapped, fld.name),
getattr(hand_built, fld.name),
f"{path}.{fld.name}" if path else fld.name,
))
return out
if isinstance(mapped, list) and isinstance(hand_built, list):
mapped_list = cast("list[object]", mapped)
hand_built_list = cast("list[object]", hand_built)
if len(mapped_list) != len(hand_built_list):
out.append(f"{path}: LEN {len(mapped_list)} vs {len(hand_built_list)}")
return out
for i, (m_item, h_item) in enumerate(zip(mapped_list, hand_built_list)):
out.extend(_diff_load_bearing(m_item, h_item, f"{path}[{i}]"))
return out
if mapped != hand_built:
if not _is_excluded_path(path):
out.append(f"{path}: mapped={mapped!r} handbuilt={hand_built!r}")
return out
def test_from_elmhurst_site_notes_matches_hand_built_000474() -> None:
# Arrange — _elmhurst_worksheet_000474.build_epc() is the canonical
# hand-built EpcPropertyData for cert U985-0001-000474; it cascades
# to the worksheet PDF's `SAP value 62.2584` at 1e-4 (cohort SAP-
# result pin). Routing the corresponding Summary PDF through the
# Elmhurst mapper MUST produce a load-bearing-field-equivalent
# EpcPropertyData; any divergence is a mapper-coverage gap.
#
# Tracer-bullet scope: cert 000474 only. Once GREEN, parametrize
# over the 5 other cohort fixtures and add cert 001479 (after
# `_elmhurst_worksheet_001479` lands at 1e-4 via Slice 62 iteration).
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000474_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
mapped = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
hand_built = _w000474.build_epc()
# Act
diffs: list[str] = []
for field_name in _LOAD_BEARING_FIELDS:
diffs.extend(_diff_load_bearing(
getattr(mapped, field_name, None),
getattr(hand_built, field_name, None),
field_name,
))
# Assert
assert not diffs, (
f"{len(diffs)} load-bearing divergence(s) between mapped and "
f"hand-built EpcPropertyData for cohort cert 000474:\n " +
"\n ".join(diffs)
)
def test_from_elmhurst_site_notes_matches_hand_built_000477() -> None:
# Arrange — _elmhurst_worksheet_000477.build_epc() is the canonical
# hand-built EpcPropertyData for cert U985-0001-000477 (single-bp
# mid-terrace, age band B, RIR with stud walls + party gables, no
# extension); it cascades to the worksheet PDF's `SAP value 65.0057`
# at 1e-4. Routing the Summary PDF through the Elmhurst mapper MUST
# produce a load-bearing-field-equivalent EpcPropertyData; any
# divergence is a mapper-coverage gap to close as its own slice.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000477_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
mapped = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
hand_built = _w000477.build_epc()
# Act
diffs: list[str] = []
for field_name in _LOAD_BEARING_FIELDS:
diffs.extend(_diff_load_bearing(
getattr(mapped, field_name, None),
getattr(hand_built, field_name, None),
field_name,
))
# Assert
assert not diffs, (
f"{len(diffs)} load-bearing divergence(s) between mapped and "
f"hand-built EpcPropertyData for cohort cert 000477:\n " +
"\n ".join(diffs)
)
def test_from_elmhurst_site_notes_matches_hand_built_000480() -> None:
# Arrange — _elmhurst_worksheet_000480.build_epc() is the canonical
# hand-built EpcPropertyData for cert U985-0001-000480 (mid-terrace
# with main + 1 extension + 19.83 m² RIR, gas combi); it cascades
# to the worksheet PDF's `SAP value 61.2986` at 1e-4. Routing the
# Summary PDF through the Elmhurst mapper MUST produce a load-
# bearing-field-equivalent EpcPropertyData; any divergence is a
# mapper-coverage gap to close as its own slice.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000480_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
mapped = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
hand_built = _w000480.build_epc()
# Act
diffs: list[str] = []
for field_name in _LOAD_BEARING_FIELDS:
diffs.extend(_diff_load_bearing(
getattr(mapped, field_name, None),
getattr(hand_built, field_name, None),
field_name,
))
# Assert
assert not diffs, (
f"{len(diffs)} load-bearing divergence(s) between mapped and "
f"hand-built EpcPropertyData for cohort cert 000480:\n " +
"\n ".join(diffs)
)
def test_from_elmhurst_site_notes_matches_hand_built_000487() -> None:
# Arrange — _elmhurst_worksheet_000487.build_epc() is the canonical
# hand-built EpcPropertyData for cert U985-0001-000487 (Enclosed
# Mid-Terrace, main + 1 extension + 21.03 m² RIR with explicit-U
# gable_wall_external, gas combi, 1 electric shower, 1.43 m²
# timber-frame alt wall on the extension); it cascades to the
# worksheet PDF's `SAP value 61.6431` at 1e-4. Routing the Summary
# PDF through the Elmhurst mapper MUST produce a load-bearing-
# field-equivalent EpcPropertyData; any divergence is a mapper-
# coverage gap to close as its own slice.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000487_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
mapped = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
hand_built = _w000487.build_epc()
# Act
diffs: list[str] = []
for field_name in _LOAD_BEARING_FIELDS:
diffs.extend(_diff_load_bearing(
getattr(mapped, field_name, None),
getattr(hand_built, field_name, None),
field_name,
))
# Assert
assert not diffs, (
f"{len(diffs)} load-bearing divergence(s) between mapped and "
f"hand-built EpcPropertyData for cohort cert 000487:\n " +
"\n ".join(diffs)
)
def test_from_elmhurst_site_notes_matches_hand_built_000490() -> None:
# Arrange — _elmhurst_worksheet_000490.build_epc() is the canonical
# hand-built EpcPropertyData for cert U985-0001-000490 (End-Terrace,
# main + 1 extension, gas combi + gas-secondary; sheltered_sides=1
# per RdSAP §S5); it cascades to the worksheet PDF's `SAP value
# 57.3979` at 1e-4. Routing the Summary PDF through the Elmhurst
# mapper MUST produce a load-bearing-field-equivalent
# EpcPropertyData; any divergence is a mapper-coverage gap.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000490_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
mapped = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
hand_built = _w000490.build_epc()
# Act
diffs: list[str] = []
for field_name in _LOAD_BEARING_FIELDS:
diffs.extend(_diff_load_bearing(
getattr(mapped, field_name, None),
getattr(hand_built, field_name, None),
field_name,
))
# Assert
assert not diffs, (
f"{len(diffs)} load-bearing divergence(s) between mapped and "
f"hand-built EpcPropertyData for cohort cert 000490:\n " +
"\n ".join(diffs)
)
def test_from_elmhurst_site_notes_matches_hand_built_000516() -> None:
# Arrange — _elmhurst_worksheet_000516.build_epc() is the canonical
# hand-built EpcPropertyData for cert U985-0001-000516 (Mid-Terrace,
# main + 19.02 m² RIR, 5 vertical windows + 1 roof window which the
# mapper routes to `sap_roof_windows` per `U > 3.0` discrimination);
# it cascades to the worksheet PDF's `SAP value 62.7937` at 1e-4.
# Routing the Summary PDF through the Elmhurst mapper MUST produce
# a load-bearing-field-equivalent EpcPropertyData.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000516_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
mapped = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
hand_built = _w000516.build_epc()
# Act
diffs: list[str] = []
for field_name in _LOAD_BEARING_FIELDS:
diffs.extend(_diff_load_bearing(
getattr(mapped, field_name, None),
getattr(hand_built, field_name, None),
field_name,
))
# Assert
assert not diffs, (
f"{len(diffs)} load-bearing divergence(s) between mapped and "
f"hand-built EpcPropertyData for cohort cert 000516:\n " +