The gov-API lodges secondary fuel as an enum whose value can COLLIDE with a
different same-valued RdSAP 10 Table 32 / SAP 10.2 Table 12 fuel code:
- enum 9 = "dual fuel (mineral and wood)" vs Table code 9 = LPG SC11F
- enum 5 = "anthracite" vs Table code 5 = LPG (bulk)
The main-fuel boundary already canonicalises these (`_GOV_API_COLLISION_
FUELS`), but the SECONDARY-heating cost + CO2/PE paths never did — they took
the bare same-value lookup, so a dual-fuel room heater was priced as LPG
(3.48 vs dual-fuel 3.99 p/kWh) and emitted as LPG (CO2 0.241 vs 0.087),
and an anthracite secondary as bulk LPG (12.19 vs 3.64 p/kWh). The price
under-count over-rates SAP; the CO2 over-count inflates emissions.
Fix: add enum 9 to `_GOV_API_COLLISION_FUELS` (5 and 33 were already there)
and canonicalise the secondary fuel code on both the cost
(`_secondary_fuel_cost_gbp_per_kwh`) and factor (`_secondary_fuel_code`)
paths, mirroring the main-fuel boundary. canonical_fuel_code only touches
{5,9,33}, so genuinely Table-coded secondaries (House coal 11, wood logs 20,
community fuels 30-32) are left unchanged — confirmed by a full-map audit.
Corpus: within-0.5 69.7% -> 70.2% (MAE 0.854 -> 0.845; dual-fuel-secondary
cohort 42.9% -> 49.0%, signed +0.55 -> +0.41) and CO2 MAE 0.12 -> 0.08 t/yr
(bias +0.04 -> 0.00). Ratcheted the corpus floors (within 0.70, MAE 0.85,
CO2 0.09, PE 4.0). A prior session deferred enum 9 ("direction not
understood") while the EPC PE/CO2 lens was confounded by the climate-cascade
bug (
|
||
|---|---|---|
| .. | ||