Model/domain
Khalim Conn-Kowlessar 2e466ed1e6 fix(wall-U): as-built "insulated (assumed)" cavity uses Cavity-as-built row, not Filled cavity
An as-built cavity wall (wall_insulation_type=4) lodged "Cavity wall, as
built, insulated (assumed)" was routed to RdSAP 10 Table 6's "Filled
cavity" row. Per Table 6 (England, PDF p.41) the Filled-cavity row carries
the "†" footnote ("assumed as built") only at age bands I-M, where it is
numerically identical to "Cavity as built"; at bands A-H the Filled-cavity
row represents a GENUINE fill, not the as-built assumption. So an as-built
cavity must use the "Cavity as built" row at all bands (band G/H = 0.60,
not the filled 0.35).

This is the same latent A-H bug slice S0380.210 fixed for the "partial
insulation (assumed)" variant but left in place for "insulated (assumed)"
by a legacy production convention. The API SAP-accuracy cohort over-rated
"Cavity wall, as built, insulated (assumed)" certs at bands G/H by a clean
+1.38 / +1.61 SAP median (n=37 / n=18); bands I-M were unaffected (rows
coincide), confirming the spec mechanism per-band.

Retires the `_cavity_described_as_filled` description sniffer — as-built
cavities now always use the as-built row regardless of the rendered
insulation adjective; a genuine retrofit fill is still caught by the
explicit wall_insulation_type=2 branch.

API SAP eval: 48.6% -> 52.1% within 0.5; <1.0 63.8% -> 67.2%; median |err|
0.548 -> 0.475; mean|err| 1.561 -> 1.497; 909 computed, 0 raises.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 18:51:17 +00:00
..
addresses standardist Address 2026-05-22 10:13:32 +00:00
data_transformation moved classifier data transformation to an easy one 2026-06-01 14:53:34 +00:00
epc Remove EPC and asset_list changes unrelated to SAL handler 2026-06-01 16:39:09 +00:00
fuel_rates feat(fuel-rates): FuelRates snapshot + repository foundation (ADR-0014) 2026-06-02 09:29:07 +00:00
geospatial feat(geospatial): GeospatialRepo — OS Open-UPRN coordinate lookup (#1131) 2026-06-01 16:28:48 +00:00
property feat(property): Property aggregate + PropertyRepository (#1132) 2026-06-01 16:28:48 +00:00
property_baseline feat(baseline): sap_code_to_fuel normalizes via the calculator's own helper 2026-06-05 18:59:25 +00:00
sap10_calculator fix(hw-cost): WHC-903 immersion off-peak HW bills at Table 13 high-rate fraction 2026-06-08 15:45:41 +00:00
sap10_ml fix(wall-U): as-built "insulated (assumed)" cavity uses Cavity-as-built row, not Filled cavity 2026-06-08 18:51:17 +00:00
tasks added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
postcode.py get rid of comments 2026-05-20 13:21:11 +00:00