"ber": 135.65,
|
|
"ser": 72.8,
|
|
"ter": 39.05,
|
|
"tyr": 114.44,
|
|
"uprn": 12457,
|
|
"status": "entered",
|
|
"postcode": "A1 1AA",
|
|
"post_town": "New Town",
|
|
"energy_use": {
|
|
"energy_consumption_current": 802.38
|
|
},
|
|
"issue_date": "2017-10-13",
|
|
"methodology": "SBEM",
|
|
"report_type": 3,
|
|
"schema_type": "CEPC-7.1",
|
|
"uprn_source": "Energy Assessor",
|
|
"valid_until": "2027-10-12",
|
|
"asset_rating": 93,
|
|
"language_code": 1,
|
|
"output_engine": "EPCgen, v5.3.a.0",
|
|
"property_type": "A1/A2 Retail and Financial/Professional services",
|
|
"address_line_1": "99a Address Street",
|
|
"address_line_2": "Place Location",
|
|
"assessment_type": "CEPC",
|
|
"inspection_date": "2017-10-10",
|
|
"inspection_type": "Physical",
|
|
"ac_questionnaire": {
|
|
"ac_present": "No",
|
|
"ac_rated_output": {
|
|
"ac_rating_unknown_flag": 1
|
|
},
|
|
"ac_inspection_commissioned": 4
|
|
},
|
|
"calculation_tool": "CLG, iSBEM, v5.3.a, SBEM, v5.3.a.0",
|
|
"is_heritage_site": "N",
|
|
"transaction_type": 6,
|
|
"registration_date": "2017-10-13",
|
|
"building_complexity": "Level 3",
|
|
"new_build_benchmark": 27,
|
|
"technical_information": {
|
|
"floor_area": 222,
|
|
"building_level": 3,
|
|
"main_heating_fuel": "Grid Supplied Electricity",
|
|
"building_environment": "Heating and Natural Ventilation"
|
|
},
|
|
"summary_of_performance": {
|
|
"building_data": [
|
|
{
|
|
"area": 221.66,
|
|
"weather": "NEW",
|
|
"activities": [
|
|
{
|
|
"id": 1078,
|
|
"area": 6.84
|
|
},
|
|
{
|
|
"id": 1077,
|
|
"area": 3.42
|
|
},
|
|
{
|
|
"id": 1074,
|
|
"area": 43.89
|
|
},
|
|
{
|
|
"id": 1305,
|
|
"area": 167.51
|
|
}
|
|
],
|
|
"building_w_k": 756.843,
|
|
"hvac_systems": [
|
|
{
|
|
"area": 54.15,
|
|
"type": "Other local room heater - fanned",
|
|
"fuel_type": "Grid Supplied Electricity",
|
|
"activities": [
|
|
{
|
|
"id": 1078,
|
|
"area": 6.84
|
|
},
|
|
{
|
|
"id": 1077,
|
|
"area": 3.42
|
|
},
|
|
{
|
|
"id": 1074,
|
|
"area": 43.89
|
|
}
|
|
],
|
|
"heat_source": "Room heater",
|
|
"cooling_sseer": 0,
|
|
"heating_sseff": 0.8,
|
|
"kwh_m2_cooling": 0,
|
|
"kwh_m2_heating": 221.413,
|
|
"cooling_gen_seer": 0,
|
|
"heating_gen_seff": 1,
|
|
"kwh_m2_auxiliary": 8.58942,
|
|
"mj_m2_cooling_dem": 82.8076,
|
|
"mj_m2_heating_dem": 637.668
|
|
},
|
|
{
|
|
"area": 167.51,
|
|
"type": "Other local room heater - unfanned",
|
|
"fuel_type": "Grid Supplied Electricity",
|
|
"activities": [
|
|
{
|
|
"id": 1305,
|
|
"area": 167.51
|
|
}
|
|
],
|
|
"heat_source": "Room heater",
|
|
"cooling_sseer": 0,
|
|
"heating_sseff": 0.8,
|
|
"kwh_m2_cooling": 0,
|
|
"kwh_m2_heating": 143.224,
|
|
"cooling_gen_seer": 0,
|
|
"heating_gen_seff": 1,
|
|
"kwh_m2_auxiliary": 0,
|
|
"mj_m2_cooling_dem": 277.439,
|
|
"mj_m2_heating_dem": 412.486
|
|
}
|
|
],
|
|
"analysis_type": "ACTUAL",
|
|
"area_exterior": 578.13,
|
|
"building_alpha": 5.48977,
|
|
"building_w_m2k": 1.30912,
|
|
"q50_infiltration": 25,
|
|
"global_performance": {
|
|
"kwh_m2_chp": 0,
|
|
"kwh_m2_dhw": 1.42751,
|
|
"kwh_m2_lpg": 0,
|
|
"kwh_m2_oil": 0,
|
|
"kwh_m2_pvs": 0,
|
|
"kwh_m2_ses": 0,
|
|
"kwh_m2_coal": 0,
|
|
"kwh_m2_wind": 0,
|
|
"kwh_m2_biogas": 0,
|
|
"kwh_m2_biomass": 0,
|
|
"kwh_m2_cooling": 0,
|
|
"kwh_m2_heating": 162.325,
|
|
"kwh_m2_lighting": 95.5093,
|
|
"kwh_m2_supplied": 261.361,
|
|
"kwh_m2_auxiliary": 2.09834,
|
|
"kwh_m2_displaced": 0,
|
|
"kwh_m2_dual_fuel": 0,
|
|
"kwh_m2_equipment": 17.0788,
|
|
"kwh_m2_smokeless": 0,
|
|
"kwh_m2_anthracite": 0,
|
|
"kwh_m2_waste_heat": 0,
|
|
"kwh_m2_natural_gas": 0,
|
|
"kwh_m2_district_heating": 0
|
|
}
|
|
},
|
|
{
|
|
"area": 221.66,
|
|
"weather": "NEW",
|
|
"activities": [
|
|
{
|
|
"id": 1078,
|
|
"area": 6.84
|
|
},
|
|
{
|
|
"id": 1077,
|
|
"area": 3.42
|
|
},
|
|
{
|
|
"id": 1074,
|
|
"area": 43.89
|
|
},
|
|
{
|
|
"id": 1305,
|
|
"area": 167.51
|
|
}
|
|
],
|
|
"building_w_k": 141.605,
|
|
"hvac_systems": [
|
|
{
|
|
"area": 54.15,
|
|
"type": "Other local room heater - fanned",
|
|
"fuel_type": "Oil",
|
|
"activities": [
|
|
{
|
|
"id": 1078,
|
|
"area": 6.84
|
|
},
|
|
{
|
|
"id": 1077,
|
|
"area": 3.42
|
|
},
|
|
{
|
|
"id": 1074,
|
|
"area": 43.89
|
|
}
|
|
],
|
|
"heat_source": "Room heater",
|
|
"cooling_sseer": 0,
|
|
"heating_sseff": 0.819,
|
|
"kwh_m2_cooling": 0,
|
|
"kwh_m2_heating": 83.8955,
|
|
"cooling_gen_seer": 0,
|
|
"heating_gen_seff": 0,
|
|
"kwh_m2_auxiliary": 2.29051,
|
|
"mj_m2_cooling_dem": 32.988,
|
|
"mj_m2_heating_dem": 247.357
|
|
},
|
|
{
|
|
"area": 167.51,
|
|
"type": "Other local room heater - unfanned",
|
|
"fuel_type": "Oil",
|
|
"activities": [
|
|
{
|
|
"id": 1305,
|
|
"area": 167.51
|
|
}
|
|
],
|
|
"heat_source": "Room heater",
|
|
"cooling_sseer": 0,
|
|
"heating_sseff": 0.819,
|
|
"kwh_m2_cooling": 0,
|
|
"kwh_m2_heating": 18.2439,
|
|
"cooling_gen_seer": 0,
|
|
"heating_gen_seff": 0,
|
|
"kwh_m2_auxiliary": 0,
|
|
"mj_m2_cooling_dem": 153.68,
|
|
"mj_m2_heating_dem": 53.7903
|
|
}
|
|
],
|
|
"analysis_type": "NOTIONAL",
|
|
"area_exterior": 578.13,
|
|
"building_alpha": 12.3616,
|
|
"building_w_m2k": 0.244936,
|
|
"q50_infiltration": 5,
|
|
"global_performance": {
|
|
"kwh_m2_chp": 0,
|
|
"kwh_m2_dhw": 1.64373,
|
|
"kwh_m2_lpg": 0,
|
|
"kwh_m2_oil": 35.9259,
|
|
"kwh_m2_pvs": 0,
|
|
"kwh_m2_ses": 0,
|
|
"kwh_m2_coal": 0,
|
|
"kwh_m2_wind": 0,
|
|
"kwh_m2_biogas": 0,
|
|
"kwh_m2_biomass": 0,
|
|
"kwh_m2_cooling": 0,
|
|
"kwh_m2_heating": 34.2821,
|
|
"kwh_m2_lighting": 53.9687,
|
|
"kwh_m2_supplied": 54.5286,
|
|
"kwh_m2_auxiliary": 0.559555,
|
|
"kwh_m2_displaced": 0,
|
|
"kwh_m2_dual_fuel": 0,
|
|
"kwh_m2_equipment": 17.0788,
|
|
"kwh_m2_smokeless": 0,
|
|
"kwh_m2_anthracite": 0,
|
|
"kwh_m2_waste_heat": 0,
|
|
"kwh_m2_natural_gas": 0,
|
|
"kwh_m2_district_heating": 0
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"existing_stock_benchmark": 79,
|
|
"related_certificate_number": "9999-9999-3333-9999-2222",
|
|
"current_energy_efficiency_band": "D"
|
|
} |