Model/domain
Jun-te Kim 8e33a8de53 test(accuracy): ratchet 77.3% -> 77.7% via flat-roof insulation-thickness fix (Elmhurst-validated)
A FLAT roof lodges its insulation thickness in the DEDICATED gov-EPC API
`flat_roof_insulation_thickness` field (e.g. "75mm"), leaving
`roof_insulation_thickness` None (that field is for pitched-loft joists).
`heat_transmission_from_cert` read only the latter, so a measured
flat-roof thickness was ignored and the roof billed at the uninsulated
age-band flat default (age E = 1.5) instead of its Table-16 insulated U.

Fixed by preferring `flat_roof_insulation_thickness` when the part is a
flat roof — the exact mirror of the existing rafter-thickness branch.
An "AB"/"NI" (as-built/unknown) value parses to None and keeps the
age-band default, unchanged; only measured thicknesses move.

PER-CERT ELMHURST VALIDATION (cert 47084930, top-floor flat, flat roof
75 mm): built on the lodged inputs in accredited Elmhurst RdSAP10-Online
(evidence saved: elmhurst_summary.pdf / elmhurst_worksheet.pdf). The
worksheet bills "insulated flat roof" at U 0.5 (floor 0.70 + wall 0.25
also matching the engine). The fix takes the engine roof 96.4 -> 32.1 W/K
(= 64.26 x 0.5, Elmhurst-exact), PE +47 -> +0.2, SAP 69.51 -> 74.34 =
lodged 74.

Gauge: within 77.3% -> 77.7%, SAP MAE 0.648 -> 0.641, CO2 0.074 -> 0.072,
PE 3.1 -> 2.97. Unit-pinned in test_heat_transmission
(flat_roof_insulation_thickness -> U 0.5); RealCertExpectation 47084930
= 74 (Elmhurst-validated). Also adds the build script build_47084930.py.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-02 23:27:57 +00:00
..
addresses standardist Address 2026-05-22 10:13:32 +00:00
billing Route an off-peak meter's electric end uses to the day/night carrier 🟩 2026-06-24 17:38:37 +00:00
data_transformation Let a deterministic guard override the fallback classifier per description 🟩 2026-07-01 09:39:50 +00:00
elmhurst more examples 2026-06-19 09:51:49 +00:00
epc Merge pull request #1429 from Hestia-Homes/fix/property-overlay-storage-category 2026-07-02 12:51:58 +01:00
epc_prediction Predict ventilation kind from the cohort mode 🟩 2026-06-26 10:54:11 +00:00
fuel_rates Expose an off-peak meter's standing charge and full day/night blend range 🟩 2026-06-24 17:14:51 +00:00
geospatial feat(geospatial): one-read spatial reference (coords + restrictions) 2026-06-04 17:13:39 +00:00
magicplan Mapper reads 'Individual Trickle Vent' label variant 🟩 2026-06-30 13:44:38 +00:00
modelling Merge pull request #1426 from Hestia-Homes/fix/hhrsh-storage-offpeak-pricing 2026-07-02 12:50:32 +01:00
property feat: thread physical-state-change signal into rebaselining 🟩 2026-06-26 19:15:11 +00:00
property_baseline Persist no Lodged Performance for a predicted Property 🟩 2026-06-30 22:10:57 +00:00
sap10_calculator test(accuracy): ratchet 77.3% -> 77.7% via flat-roof insulation-thickness fix (Elmhurst-validated) 2026-07-02 23:27:57 +00:00
sap10_ml test(accuracy): ratchet SAP MAE 0.658 -> 0.647 via wall added-insulation unknown-thickness default 2026-07-02 20:24:56 +00:00
tasks new application to trigger e2e for a single property and scenario 2026-06-22 12:54:53 +00:00
building_geometry.py feat(modelling): floor Recommendation Generator + ground-floor-area geometry 2026-06-03 09:12:29 +00:00
postcode.py get rid of comments 2026-05-20 13:21:11 +00:00