Model/domain
Jun-te Kim 0e784cbb1c test(accuracy): ratchet SAP MAE 0.658 -> 0.647 via wall added-insulation unknown-thickness default
A SOLID-BRICK or STONE wall lodging External/Internal insulation
(wall_insulation_type 1/3) but no measured insulation thickness (gov-API
"NI" -> None) was billed at its UNINSULATED §5.6/Table-6 U-value: the §5.8
added-insulation R-value adjustment gates on `insulation_thickness_mm > 0`,
so an unknown thickness fell straight through to the raw solid-wall U
(~1.4-1.7). This over-counted wall heat loss and under-rated the dwelling.

RdSAP 10 §5.4 (PDF p.32): "the U-value with additional insulation is based
on the thickness of insulation of mineral wool type (assume 100 mm if
thickness is unknown)". Apply that 100 mm default so the §5.8 Table-14
R-value fires. Scoped to solid brick / stone (the only constructions with
a §5.8 R-value path in u_wall) so cavity (composite path) and timber /
system-built walls are untouched.

Localised by deep-diving corpus cert 200004296092 (end-terrace, solid
brick 360 mm "with external insulation", NI): walls 101.7 W/K (U~1.40,
HLP 3.46 = absurd for an insulated wall) -> ~0.29; PE +59.6 -> ~0; engine
64.35 (Δ -6.65) -> 71.74 = lodged 71. ~8 solid-brick/stone corpus certs
carry this NI-thickness-with-insulation shape.

Gauge: within-0.5 held at 77.0%, SAP MAE 0.658 -> 0.647, CO2 0.074 ->
0.073, PE 3.2 -> 3.1 (floor ratcheted). Unit-pinned in test_rdsap_uvalues
(brick 360 mm external NI -> 0.29) + RealCertExpectation 200004296092 = 72.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-02 20:24:56 +00:00
..
addresses standardist Address 2026-05-22 10:13:32 +00:00
billing Route an off-peak meter's electric end uses to the day/night carrier 🟩 2026-06-24 17:38:37 +00:00
data_transformation Let a deterministic guard override the fallback classifier per description 🟩 2026-07-01 09:39:50 +00:00
elmhurst more examples 2026-06-19 09:51:49 +00:00
epc Merge pull request #1429 from Hestia-Homes/fix/property-overlay-storage-category 2026-07-02 12:51:58 +01:00
epc_prediction Predict ventilation kind from the cohort mode 🟩 2026-06-26 10:54:11 +00:00
fuel_rates Expose an off-peak meter's standing charge and full day/night blend range 🟩 2026-06-24 17:14:51 +00:00
geospatial feat(geospatial): one-read spatial reference (coords + restrictions) 2026-06-04 17:13:39 +00:00
magicplan Mapper reads 'Individual Trickle Vent' label variant 🟩 2026-06-30 13:44:38 +00:00
modelling Merge pull request #1426 from Hestia-Homes/fix/hhrsh-storage-offpeak-pricing 2026-07-02 12:50:32 +01:00
property feat: thread physical-state-change signal into rebaselining 🟩 2026-06-26 19:15:11 +00:00
property_baseline Persist no Lodged Performance for a predicted Property 🟩 2026-06-30 22:10:57 +00:00
sap10_calculator test(accuracy): ratchet SAP MAE 0.668 -> 0.658 via instantaneous-electric-DHW off-peak fix 2026-07-02 20:04:58 +00:00
sap10_ml test(accuracy): ratchet SAP MAE 0.658 -> 0.647 via wall added-insulation unknown-thickness default 2026-07-02 20:24:56 +00:00
tasks new application to trigger e2e for a single property and scenario 2026-06-22 12:54:53 +00:00
building_geometry.py feat(modelling): floor Recommendation Generator + ground-floor-area geometry 2026-06-03 09:12:29 +00:00
postcode.py get rid of comments 2026-05-20 13:21:11 +00:00