Model/tests/domain/sap10_calculator
Khalim Conn-Kowlessar 872bc585f7 fix(hot-water): apply Table 12c distribution loss to HW-only heat networks (whc 950/951/952)
The heat-network HW distribution-loss override fired only when the MAIN was
a heat network AND whc inherited from main ({901,902,914}). Water-heating-only
heat networks (SAP 10.2 Table 4a HW codes 950 boilers / 951 CHP / 952 heat
pump) were missed entirely: their Table 4a plant efficiency applied with NO
distribution loss, so the HW fuel was under-counted by the Table 12c DLF
(1.33-1.48x) → under-cost → over-rate.

RdSAP 10 §10 (spec p.36): a water-heating-only heat network is calculated 'for
plant efficiency, distribution loss and pumping energy - see Table 12c'. Added
a whc-gated branch (independent of the main) applying water_eff = plant_eff /
DLF — the per-kWh-generated cost model (q_generated = q_useful x DLF). Fires on
the WHC alone so a HW-only heat network with a non-network main (cert 9093, whc
950 + warm-air main 502) is covered.

The 3 corpus whc=950 certs all improve in |err|: 2153 +2.62->-0.48 (now within
0.5), 7220 +1.27->-0.97, 9093 +6.04->+3.60 (residual is its warm-air main, a
separate cause). within-0.5 56.66->56.79%, within-1.0 71.9->72.2%, mean|err|
down; only those 3 certs change. New AAA test pins the DLF scaling fires on the
WHC independent of the main. Goldens + gate green, pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 13:40:17 +00:00
..
climate Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
rdsap fix(hot-water): apply Table 12c distribution loss to HW-only heat networks (whc 950/951/952) 2026-06-09 13:40:17 +00:00
validation Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
worksheet fix(wall-U): apply RdSAP Table 4 "Sheltered" R=0.5 to alternative walls 2026-06-08 22:49:42 +00:00
__init__.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_bre_worked_examples.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_calculator.py feat(calculator): thread per-end-use fuel codes + PV export onto SapResult 2026-06-05 18:59:24 +00:00
test_pcdb_etl.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_322_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_329_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_362_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_postcode_weather.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_table_12.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_table_12a.py fix(tariff): Unknown meter + storage/CPSU main → off-peak (§12) 2026-06-06 19:02:34 +00:00
test_table_13.py fix(hw-cost): WHC-903 immersion off-peak HW bills at Table 13 high-rate fraction 2026-06-08 15:45:41 +00:00
test_table_32.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00