Khalim Conn-Kowlessar 94275d07cc fix(hot-water): default present-but-unsized cylinder to Table 28 Normal 110 L
RdSAP 10 §10.5 (PDF p.55): "If the actual size is not determined, the size of
a hot-water cylinder is taken as according to Table 28." When a cylinder is
present (has_hot_water_cylinder) but no size descriptor resolves — the gov API
lodges cylinder_size=0, or Exact with no measured volume — `_hot_water_
cylinder_volume_l` returned None, silently dropping BOTH the cylinder's
storage loss and the Table 13 electric-DHW high-rate fraction, under-costing
and over-rating the dwelling. Default such cylinders to the Table 28 baseline
"Normal" 110 L (the value §10.7 also instantiates as the first-row default).

The context-dependent Inaccessible 210/160 values are deliberately NOT applied
here — they are tied to the explicit "Inaccessible" descriptor (code 5) the
assessor lodges, not to an unpopulated size field.

Scope: 7 of 301 cylinder certs in the corpus (2%). Correctness fix — closes a
real spec gap; marginal on the headline (within-0.5 66.1% unchanged, MAE
1.128 -> 1.124) because these certs' residual is dominated by a separate HW-
demand gap, not the cylinder. Worksheet harness 47/47 0 diverge (Summary certs
lodge a real size, so the fallback never fires). 1 AAA test, pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-14 08:20:34 +00:00
..
__init__.py python upgraded due to enum 2026-06-12 15:47:28 +00:00
conftest.py python upgraded due to enum 2026-06-12 15:47:28 +00:00
test_client.py python upgraded due to enum 2026-06-12 15:47:28 +00:00
test_mapper_corpus.py python upgraded due to enum 2026-06-12 15:47:28 +00:00
test_mapper_dispatcher.py python upgraded due to enum 2026-06-12 15:47:28 +00:00
test_sap_accuracy_corpus.py fix(hot-water): default present-but-unsized cylinder to Table 28 Normal 110 L 2026-06-14 08:20:34 +00:00