mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-07-22 08:48:38 +00:00
The committed gate needs frozen, reproducible data without dumping real UK addresses into the repo. Add: - harness anonymise_payload + stable_hash: hash street address + cert number into opaque, dedup-stable tokens; blank secondary address lines + post_town; keep postcode + all component/lodged fields (gov data is OGL). Unit-tested. - scripts/build_epc_prediction_fixture.py: curate qualifying postcodes (>=1 SAP 10.2 target + >=2 distinct addresses) from the local scratch corpus, anonymise, freeze under tests/fixtures/epc_prediction/. - The frozen fixture: 15 postcodes / 280 certs / 36 SAP-10.2 targets. Verified no plaintext address_line_1 and post_town all blank. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
1 line
No EOL
7.2 KiB
JSON
1 line
No EOL
7.2 KiB
JSON
{"uprn": 100090075246, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE7 1NT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "", "built_form": 3, "created_at": "2024-03-08 11:04:52", "door_count": 1, "glazed_area": 4, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 15101}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.94, "sap_windows": [{"pvc_frame": "true", "glazing_gap": "16+", "orientation": 8, "window_area": {"value": 2.57, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 4, "window_area": {"value": 2.99, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"orientation": 4, "window_area": {"value": 3.69, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}], "schema_type": "RdSAP-Schema-20.0.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "addr-ebbcec3eef49", "address_line_2": "", "assessment_type": "RdSAP", "completion_date": "2024-03-08", "inspection_date": "2024-03-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2024-03-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.09, "quantity": "square metres"}, "party_wall_length": {"value": 7.16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 27.62, "quantity": "square metres"}, "party_wall_length": {"value": 7.16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 672, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 581, "currency": "GBP"}, "hot_water_cost_current": {"value": 232, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 570, "currency": "GBP"}, "indicative_cost": "\u00a33,500 - \u00a35,500", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "20.0.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 78, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 137, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2580, "impact_of_loft_insulation": -177, "space_heating_existing_dwelling": 6089}, "energy_consumption_current": 235, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "4.13r0001", "energy_consumption_potential": 81, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 8} |