mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-07-19 08:53:17 +00:00
The committed gate needs frozen, reproducible data without dumping real UK addresses into the repo. Add: - harness anonymise_payload + stable_hash: hash street address + cert number into opaque, dedup-stable tokens; blank secondary address lines + post_town; keep postcode + all component/lodged fields (gov data is OGL). Unit-tested. - scripts/build_epc_prediction_fixture.py: curate qualifying postcodes (>=1 SAP 10.2 target + >=2 distinct addresses) from the local scratch corpus, anonymise, freeze under tests/fixtures/epc_prediction/. - The frozen fixture: 15 postcodes / 280 certs / 36 SAP-10.2 targets. Verified no plaintext address_line_1 and post_town all blank. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
1 line
No EOL
8.2 KiB
JSON
1 line
No EOL
8.2 KiB
JSON
{"uprn": 100090075283, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE7 1NT", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "", "built_form": 4, "created_at": "2019-07-19 15:36:07.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "addr-a958c367372f", "address_line_2": "", "assessment_type": "RdSAP", "completion_date": "2019-07-19", "inspection_date": "2019-07-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2019-07-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 265, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.91, "quantity": "square metres"}, "party_wall_length": {"value": 14.32, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 27.71, "quantity": "square metres"}, "party_wall_length": {"value": 14.32, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 481, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 323, "currency": "GBP"}, "hot_water_cost_current": {"value": 200, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 8, "typical_saving": {"value": 339, "currency": "GBP"}, "indicative_cost": "5,500", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.7, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 77, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 77, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3257, "impact_of_loft_insulation": -445, "space_heating_existing_dwelling": 6328}, "energy_consumption_current": 330, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.10r02", "energy_consumption_potential": 67, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 8} |