Model/backend/documents_parser/tests
Khalim Conn-Kowlessar 9ed003a503 Slice S0380.169: EES "NON" → electricity (no-system unblock per SAP 10.2 §A.2.2)
Adds `"NON": 30` to `_ELMHURST_MAIN_HEATING_EES_TO_FUEL_CODE` so the
mapper can derive the main heating fuel for the Elmhurst "no main
heating system" lodging (§14.0 Main Heating EES = NON + SAP code
699 + §14.1 Heating Type = None).

SAP 10.2 §A.2.2: "When no main heating system is identified, the
calculation is for the assumed system consisting of portable electric
heaters." Routes the fuel to Table 32 standard-electricity code 30
(tariff resolved separately from `meter_type` per `_rdsap_tariff`).

Pre-slice the cascade raised `MissingMainFuelType` per S0380.132.
Post-slice the cascade closes most of the way:

  no system: ΔSAP_c +1.18,  Δcost −£27, ΔCO2 −50, ΔPE −562

The residuals are cascade-side (likely §A.2.2 portable-electric
efficiency / responsiveness / control-type defaults differ slightly
from Elmhurst) — pinned at observed values as forcing function for
follow-up.

Moves `no system` out of `_BLOCKED_BY_MISSING_MAIN_FUEL_TYPE` into
`_EXPECTATIONS`. Blocked tier now: 5 community-heating variants.

Tests:
  - test_elmhurst_main_heating_ees_maps_no_system_code_to_electricity
  - corpus pin: no system expected residuals at observed values

916 pass / 0 fail.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-02 10:22:48 +00:00
..
fixtures Slice S0380.52: cert 000565 Elmhurst-only mapper-driven cascade pin + glazing-label coverage 2026-05-28 22:03:52 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
test_elmhurst_end_to_end.py Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
test_elmhurst_extractor.py extract window frame details from elmhurst site notes 🟥 2026-04-27 15:50:25 +00:00
test_end_to_end.py P6.1 follow-on: unbox BuildingPartIdentifier at backend boundaries 2026-05-20 09:58:23 +00:00
test_extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
test_heating_systems_corpus.py Slice S0380.169: EES "NON" → electricity (no-system unblock per SAP 10.2 §A.2.2) 2026-06-02 10:22:48 +00:00
test_pdf.py rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
test_summary_pdf_mapper_chain.py Slice S0380.143: RdSAP 10 §10.11 Table 29 — derive cylinder insulation defaults from construction age band when §15.1 lodges "No Access" 2026-05-31 21:03:10 +00:00