RdSAP 10 §5.14 (PDF p.47) "U-value of floor above a partially heated space": > "The U-value of a floor above partially heated premises is taken as > 0.7 W/m²K. This applies typically for a flat above non-domestic > premises that are not heated to the same extent or duration as the > flat." Cert 000565 Ext1 lodges Summary §9 "Location: P Above partially heated space" + "Default U-value: 0.70". Worksheet line (28b) confirms "Exposed floor Ext1 ... 34.0000 0.7000 23.8000". Pre-slice the cascade routed BP[1] floor through the BS EN ISO 13370 ground-floor formula (the "else" branch of the floor U-value dispatch in `heat_transmission.py`) — producing cascade U=0.76 vs spec 0.70. Over-counted floor heat loss by (0.76 − 0.70) × 34 m² = +2.04 W/K on the part subtotal and on the total HTC. Slice span (4 layers): 1. **Helper** — `u_floor_above_partially_heated_space()` in `domain/sap10_ml/rdsap_uvalues.py`, verbatim spec constant 0.7 (no age-band / insulation-thickness inputs). Lives in `sap10_ml` per [[project-sap10_ml-deprecation]] (edit existing file fine). 2. **Schema** — `SapFloorDimension.is_above_partially_heated_space: bool = False` (parallel to existing `is_exposed_floor`). Mutually exclusive with the exposed-floor / basement-floor branches. 3. **Mapper** — new `_is_floor_above_partially_heated_space(location)` helper detecting "above partially heated" in the Elmhurst §9 floor location string. Plumbed into `_map_elmhurst_building_part` floor- dim construction; only applies to the ground floor (i==0). 4. **Cascade** — `heat_transmission.py` adds a new branch between the exposed-floor and ground-floor branches: `is_above_partial → u_floor_above_partially_heated_space()`. Cert 000565 movement (HEAD `a7894b11` → this slice): - cascade floor_w_per_k: 72.41 → 70.37 (Δ +10.74 → Δ +8.70) - cascade BP[1] floor U: 0.76 → 0.70 (✓ EXACT vs ws 0.70) - sap_score (integer): 29 ✓ EXACT (unchanged — at goal) - sap_score_continuous: 28.7663 → 28.8131 (+0.0468 drift) - space_heating_kwh: −367 → −427 (small drift further under) - main_heating_fuel: −216 → −251 (downstream of SH) - co2_kg_per_yr: −32 → −37 - total_fuel_cost_gbp: −23 → −27 - hot_water_kwh: ✓ 0 EXACT unchanged The small continuous-SAP drift is the expected arithmetic of closing a single component when adjacent components remain unclosed (floor +10.74 was cancelling thermal_bridging −11.76 + roof −7.94 at the net-HTC level). Per [[feedback-zero-error-strict]] + [[feedback- spec-citation-in-commits]] the spec-correct slice ships regardless of transient continuous-SAP drift; remaining residual components (floor +8.70 from BP[2] Ext2 lodged 200 mm insulation thickness; roof −7.94; thermal_bridging −11.76; walls −1.67) each get their own spec-cited slice. Cohort safety: only cert 000565 Ext1 in the cohort lodges "Above partially heated space". All other Elmhurst cohort fixtures + 9 golden + 38 cohort-2 API certs default to `is_above_partially_ heated_space=False` so cascade behaviour is unchanged. Test baseline: 583 pass + 8 expected `000565` fails (was 582 + 8; +1 new mapper-chain test). Pyright net-zero per touched file (1/65/1/32/13/13 preserved). Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com> |
||
|---|---|---|
| .. | ||
| epc | ||
| magicplan | ||
| __init__.py | ||
| datatypes.py | ||
| enums.py | ||