A Simplified room-in-roof (RdSAP 10 §3.9.1, PDF p.21) does NOT measure
its slope / flat-ceiling / stud-wall surfaces — the Elmhurst Summary
lodges placeholder Length/Height cells (a 40 m flat-ceiling height, a
32 m slope on a 4.65 m-wide gable). The spec instead derives one
timber-framed "remaining area" from the floor area:
A_RR = 12.5 × √(A_RR_floor / 1.5) §3.9.1(d)
A_RR_final = A_RR − ΣA_RR_gable/other §3.9.1(e)
The cascade already computes A_RR_final itself (heat_transmission.py:
`12.5 × √(A_RR_floor/1.5) − rr_walls_in_a_rr_area` residual), but only
when `detailed_surfaces` carries no roof-going kind (`has_roof_lodgement`
gate). `_map_elmhurst_rir_surface` emitted the placeholder slope/ceiling
rows as raw L×H for every assessment type, flipping that gate and billing
1024 m² + 160 m² of explicit roof area — a 7.5× fabric-heat-loss
explosion (cert 001431 sim case 2: SAP −14.6 vs worksheet 69, space
heating 114 378 vs ~15 000 kWh).
Fix: for a Simplified assessment, drop the roof-going surfaces in the
mapper so the cascade's residual formula fires. This matches how the API
path already (correctly) handles the same Simplified RR — scalar gable
fields, no roof-going detailed_surfaces (golden cert 6035) — and the
gables-only cert 000565. Detailed (§3.10) assessments still measure these
surfaces and keep them.
With the fix, sim case 2 total external area = 232.94 (worksheet exact),
roof 78.33 (was 2725.89), SAP 69.29 → worksheet integer 69. A small
residual (~450 kWh main fuel) remains — a separate fabric gap to walk
next. 2308 passed (+2), 0 failed; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||