RdSAP10 §15 p.66 (Rounding of data):
"All element areas (gross) including window areas and
conservatory wall area: 2 d.p."
Certs 2800 and 4800 lodge heat_loss_perimeter = 21.25 m and
room_height = 2.30 m. The exact-decimal products
21.25 * 2.30 = 48.8750 (gross wall area)
6.25 * 2.30 = 14.3750 (party wall area)
sit ON the HALF_UP rounding boundary and must round to 48.88
and 14.38 m^2. Float representation drops them BELOW the
boundary:
21.25 (float) * 2.30 (float) ~= 48.87499...
HALF_UP 2 d.p. = 48.87
6.25 (float) * 2.30 (float) ~= 14.37499...
HALF_UP 2 d.p. = 14.37
The 0.01 m^2 area shortfall feeds into (29a) net wall area and
(32) party wall area, and into (31) total external area for
(36) thermal bridging — propagating a +0.0007 SAP residual via
the U-weighted heat-loss sums.
Adds `_decimal_round_half_up_sum` helper and routes both
gross-wall and party-wall sums through it, mirroring the
S0380.34 fix on `_living_area_fraction`. Certs that sit off
the .005 boundary (i.e. nearly all) are unaffected; certs
that land on it close from +0.0007 → <5e-5.
Cohort-2 distribution after S0380.31..S0380.35:
38 exact (was 36 exact + 2 <=0.07).
Cohort-1 ASHP cohort: 9/9 <1e-4 (unchanged).
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||