Model/backend/documents_parser/tests
Khalim Conn-Kowlessar b0a47cda05 fix(elmhurst-mapper): strip interleaved Alternative-wall fragments from glazing label
When a property lodges an Alternative Wall, pdftotext interleaves the §11
"Location" column ("Alternative wall 1") into the wrapped glazing-TYPE cell,
producing labels like "Double between 2002 Alternative wall and 2021 1
Alternative wall" (cert 001431 storage-heater variants, simulated case 34).

The existing greedy trailing-suffix strip (\s+Alternative wall.*$) truncates
at the FIRST "Alternative wall", losing "and 2021" and yielding the
unmatchable "Double between 2002". Added a fallback that removes EVERY
"<External|Alternative|Party> wall [n]" fragment and any stray 1-2 digit
location index from the raw label, then retries the lookup. Loss-free: no
glazing-type key contains a wall-location phrase or a bare 1-2 digit number
(install-date years are 4 digits).

Unblocks the Summary cascade for any property with an Alternative Wall;
Summary-path only (the API path receives structured glazing codes, so the
API gauge is unaffected). Regression gate green (1 pre-existing fail
unrelated).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 07:07:08 +00:00
..
fixtures fix(elmhurst-mapper): map "Bottled gas" main fuel to bottled LPG, not mains gas 2026-06-10 08:48:15 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
test_elmhurst_end_to_end.py Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
test_elmhurst_extractor.py fix(extractor): drop windows-table header remnant from first window glazing type 2026-06-02 22:54:49 +00:00
test_end_to_end.py P6.1 follow-on: unbox BuildingPartIdentifier at backend boundaries 2026-05-20 09:58:23 +00:00
test_extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
test_heating_systems_corpus.py feat(elmhurst-extractor): capture section 15.1 Immersion Heater (Dual/Single) 2026-06-10 22:16:21 +00:00
test_pdf.py rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
test_room_heater_worksheet_001431.py S0380.239: system-build walls take masonry structural infiltration (0.35) 2026-06-05 19:00:02 +00:00
test_summary_pdf_mapper_chain.py fix(elmhurst-mapper): strip interleaved Alternative-wall fragments from glazing label 2026-06-11 07:07:08 +00:00