Model/datatypes/epc
Khalim Conn-Kowlessar b2b6f8e954 fix(mapper): map Elmhurst "Value known" cylinder to measured volume (code 6)
The Elmhurst Summary §15.1 lodges "Cylinder Size: Value known" with the
measured volume in the "Cylinder Volume (l)" line — the Summary-path
equivalent of the gov-API "Exact" descriptor. The mapper had no entry for
"Value known" so `_elmhurst_cylinder_size_code` raised UnmappedElmhurstLabel,
and even once mapped the measured volume was never threaded through, so the
cascade dropped the cylinder storage loss (~468 kWh/yr) from (219) water
heating on every measured-volume-cylinder Summary.

Per RdSAP 10 §10.5 Table 28 (p.55) a measured cylinder volume is used
directly. Map "Value known" → cascade code 6 (Exact) and thread the §15.1
"Cylinder Volume (l)" value into SapHeating.cylinder_volume_measured_l, which
`_cylinder_volume_l_from_code` (cert_to_inputs.py:5281) already reads for
code 6 — mirroring the gov-API path (mapper.py:1575/1885).

Pins simulated case 39 (P960-0001-001431): an age-A mid-terrace on direct-
acting electric room heaters (SAP code 691, cat 10, control 2602) with
electric-immersion DHW off a 117 L "Value known" cylinder. The full
extractor→mapper→calculator cascade now reproduces the worksheet's SAP-rating
block EXACTLY — SAP value 36.6365 (band F) and (272) CO2 2056.0731 kg/yr,
with (219) water heating 2637.5049 and (255) total energy cost 1802.0039.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-15 23:57:25 +00:00
..
domain fix(mapper): map Elmhurst "Value known" cylinder to measured volume (code 6) 2026-06-15 23:57:25 +00:00
loaders demo generated for use in address2uprn 2026-05-08 14:48:15 +00:00
schema fix(mapper): handle 'ND' multiple_glazing_type on RdSAP-Schema-20.0.0 2026-06-15 06:43:55 +00:00
search bolstering testing 2026-04-28 13:46:09 +00:00
surveys fix(mapper): map Elmhurst "Value known" cylinder to measured volume (code 6) 2026-06-15 23:57:25 +00:00
__init__.py testing out rebaselining 2026-02-12 22:25:03 +00:00
construction_age_band.py testing out rebaselining 2026-02-12 22:25:03 +00:00
efficiency.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
floor.py preparing partiy class 2026-02-05 08:54:27 +00:00
fuel.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
heating_controls.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
hotwater.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
main_heating.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
property_type_built_form.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
roof.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
walls.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
windows.py testing out rebaselining 2026-02-12 22:25:03 +00:00