Model/tests/domain/sap10_calculator
Khalim Conn-Kowlessar b2b6f8e954 fix(mapper): map Elmhurst "Value known" cylinder to measured volume (code 6)
The Elmhurst Summary §15.1 lodges "Cylinder Size: Value known" with the
measured volume in the "Cylinder Volume (l)" line — the Summary-path
equivalent of the gov-API "Exact" descriptor. The mapper had no entry for
"Value known" so `_elmhurst_cylinder_size_code` raised UnmappedElmhurstLabel,
and even once mapped the measured volume was never threaded through, so the
cascade dropped the cylinder storage loss (~468 kWh/yr) from (219) water
heating on every measured-volume-cylinder Summary.

Per RdSAP 10 §10.5 Table 28 (p.55) a measured cylinder volume is used
directly. Map "Value known" → cascade code 6 (Exact) and thread the §15.1
"Cylinder Volume (l)" value into SapHeating.cylinder_volume_measured_l, which
`_cylinder_volume_l_from_code` (cert_to_inputs.py:5281) already reads for
code 6 — mirroring the gov-API path (mapper.py:1575/1885).

Pins simulated case 39 (P960-0001-001431): an age-A mid-terrace on direct-
acting electric room heaters (SAP code 691, cat 10, control 2602) with
electric-immersion DHW off a 117 L "Value known" cylinder. The full
extractor→mapper→calculator cascade now reproduces the worksheet's SAP-rating
block EXACTLY — SAP value 36.6365 (band F) and (272) CO2 2056.0731 kg/yr,
with (219) water heating 2637.5049 and (255) total energy cost 1802.0039.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-15 23:57:25 +00:00
..
climate Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
rdsap fix(electric-heaters): code-699 "electric heaters assumed" bills Table 12a direct-acting split 2026-06-14 09:16:22 +00:00
validation Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
worksheet fix(mapper): map Elmhurst "Value known" cylinder to measured volume (code 6) 2026-06-15 23:57:25 +00:00
__init__.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_bre_worked_examples.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_calculator.py feat(calculator): thread per-end-use fuel codes + PV export onto SapResult 2026-06-05 18:59:24 +00:00
test_pcdb_etl.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_322_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_329_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_362_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_postcode_weather.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_table_12.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_table_12a.py fix(tariff): Unknown meter + storage/CPSU main → off-peak (§12) 2026-06-06 19:02:34 +00:00
test_table_13.py fix(water-heating): 18-/24-hour immersion DHW bills 100% low-rate (Table 12a scope) 2026-06-10 22:01:35 +00:00
test_table_32.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00