🎯 Closes the 7th and final ASHP cohort cert. Summary path now
mirrors the API path's complete cohort closure at the ±0.07 spec
precision floor.
Cert 9418-3062-8205-3566-7200 (Summary_000902.pdf): Daikin Altherma
EDLQ05CAV3 (PCDB 102421 — distinct from the rest of the cohort's
Mitsubishi 104568), end-terrace house, TWO 1.64 kWp PV arrays (N+S),
210 L cylinder, `heating_duration_code='24'` (continuous heating).
Worksheet "SAP value" lodges 84.6305.
Single-line fix to
`_ELMHURST_CYLINDER_SIZE_LABEL_TO_SAP10`:
+ "Large": 4,
extending Slice S0380.6's "Medium" → 3 mapping to also cover the
"Large" cylinder. Without it `_elmhurst_cylinder_size_code('Large',
True)` returned None → cascade routed off the HP-with-cylinder HW
path → HW kWh under by 466 (Summary 1404 vs API 1871 vs
worksheet-implied 1871 via (64)/(216) divide).
Forcing function: cert 9418 first-attempt Summary SAP closes from
Δ +2.5973 (lookup miss) to Δ **+0.0296** — within ±0.07. The PV
multi-array Slice S0380.9 work was already sufficient for cert
9418's two-array PV layout (1.64 kWp N + 1.64 kWp S surfaced
correctly first-try).
ASHP cohort closure: 7/7 at spec floor:
cert Δ vs worksheet
0380 +0.0594
0350 +0.0458
2225 +0.0441
2636 +0.0323
3800 +0.0442
9285 +0.0502
9418 +0.0296 ← this slice
───────────────
mean +0.0437
Identical disposition to the API path's cohort closure at slice
102f (commit
|
||
|---|---|---|
| .. | ||