Slice 46c left the chain at SAP Δ=0.26 vs the Elmhurst worksheet PDF's 62.2584. The user rejected the 0.5 tolerance: because the cascade reproduces Elmhurst exactly on hand-built inputs and the Summary PDF carries the same source-of-truth data, the mapped path must hit 1e-4 like every other Elmhurst worksheet pin. This commit: - Tightens `test_summary_000474_full_chain_sap_matches_worksheet_pdf_exactly` from 0.5 to 1e-4. Currently fails with Δ=0.2611 — the forcing function for the next slice. - Replaces the stale `docs/sap-spec/NEXT_AGENT_PROMPT.md` with a fresh handover identifying the two remaining diffs: * pumps_fans_kwh_per_yr 130 vs 160 (30 kWh; likely `central_heating_pump_age` not plumbed) * Window [4] mis-classified as SE (4) instead of E (3); `_compose_window_descriptors` over-joins suffix tokens - Documents the architectural smell (3-schema chain ElmhurstSiteNotes → EpcPropertyData → CalculatorInputs may be over-engineered). - Lists end-goal: API-path < 0.5 SAP (rounded integers), Elmhurst-path < 1e-4 SAP (unrounded worksheet pins), then replicate for the other 5 Summary PDFs. Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com> |
||
|---|---|---|
| .. | ||
| HANDOVER_NEXT.md | ||
| NEXT_AGENT_PROMPT.md | ||
| pcdb10.dat | ||
| pcdb_table_105_gas_oil_boilers.jsonl | ||
| pcdb_table_122_solid_fuel_boilers.jsonl | ||
| pcdb_table_143_micro_cogen.jsonl | ||
| pcdb_table_313_flue_gas_heat_recovery.jsonl | ||
| pcdb_table_353_waste_water_heat_recovery.jsonl | ||
| pcdb_table_362_heat_pumps.jsonl | ||
| pcdb_table_391_high_heat_retention_storage_heaters.jsonl | ||
| pcdb_table_506_heat_interface_units.jsonl | ||
| rdsap-10-specification-2025-06-10.pdf | ||
| sap-10-2-full-specification-2025-03-14.pdf | ||
| sap-10-3-full-specification-2026-01-13.pdf | ||
| SAP_CALCULATOR.md | ||