SAP 10.2 Table 4a (PDF p.163-164) heat-pump rows split efficiency into
two columns — "space" and "water":
Code System space water
211 Ground source HP with flow temp <= 35°C 230 170
213 Water source HP with flow temp <= 35°C 230 170
215 Gas-fired GSHP with flow temp <= 35°C 120 84
216 Gas-fired WSHP with flow temp <= 35°C 120 84
217 Gas-fired ASHP with flow temp <= 35°C 110 77
521 Warm-air electric GSHP 230 170
523 Warm-air electric WSHP 230 170
525 Warm-air gas-fired GSHP 120 84
526 Warm-air gas-fired WSHP 120 84
527 Warm-air gas-fired ASHP 110 77
The split reflects real physics: heat pumps lose efficiency raising
water to ~55°C DHW temperatures vs ~35°C space-heating flow. ASHP
"in other cases" (codes 214, 221, 223, 224) and the "other cases"
gas-fired rows (225-227) have space == water = 170 / 84 / 77 — no
distinct DHW column.
Pre-slice the cascade routed WHC ∈ {901, 902, 914} ("HW from main
heating") through `seasonal_efficiency(main_code)`, which only consults
the Space column. For SAP code 211 the cascade returned 2.30 (= space)
when the spec requires 1.70 (= water). HW fuel kWh undercounted by
26% on the heating-systems corpus gshp variant: cascade 841.47 kWh vs
worksheet 1138.46 kWh.
New `_TABLE_4A_HEAT_PUMP_WATER_EFFICIENCY` dict (10 codes where Space
≠ Water) consulted in `_water_efficiency_with_category_inherit` before
falling through to the existing `seasonal_efficiency` path. Codes
where Space == Water keep the legacy inheritance — no behaviour
change. Non-HP main heating (boilers, storage heaters) likewise
unchanged.
Closures (gshp variant — SAP code 211 + WHC=901 + cylinder):
HW fuel kWh: 841.47 → 1138.45 (matches worksheet 1138.46)
ΔSAP_c: +0.9373 → -0.0178
Δcost: -£21.60 → +£0.41
ΔCO2: -34.98 → +7.06 kg/yr
ΔPE: -418.92 → +33.52 kWh/yr
No regressions on 40 other corpus variants — gshp is the only fixture
that lodges a heat-pump code with diverging Space/Water columns.
Cohort-1 ASHP closure (S0380.28 reciprocal interpolation) is unaffected
because that path runs through `heat_pump_record` PCDB Appendix N3
when a PCDB Table 362 record is lodged; this fix is the Table 4a
fallback for cases without a PCDB record.
Extended handover suite: 899 pass / 0 fail. Pyright net-zero (43 → 43).