Khalim Conn-Kowlessar bf62738787 Slice S0380.127: resolve Elmhurst "No Access" cylinder via RdSAP 10 Table 28
Elmhurst Summary §15.1 sometimes lodges "Cylinder Size: No Access" (the
inaccessible-cylinder lodging form). Pre-slice the mapper strict-raised
`UnmappedElmhurstLabel` because `_ELMHURST_CYLINDER_SIZE_LABEL_TO_SAP10`
only carried the three lodged-size labels (Normal/Medium/Large).

Per RdSAP 10 Specification Table 28 page 55 ("Cylinder size"):

  > "Inaccessible:
  >   - if off-peak electric dual immersion: 210 litres
  >   - if from solid fuel boiler: 160 litres
  >   - otherwise: 110 litres"

And per §10.5.1 page 53:

  > "An electric immersion is assumed dual in the following cases:
  >  - cylinder is inaccessible and electricity tariff is dual"

So the 210-L "off-peak electric dual immersion" branch fires automatically
when both (a) cylinder is inaccessible AND (b) water heating is electric
AND (c) meter type is dual / off-peak (no separate dual-immersion lodging
required).

New helper `_resolve_elmhurst_inaccessible_cylinder_size` keys off
§15.0 "Water Heating Fuel Type" + §14.2 "Electricity meter type":

  - solid fuel water heating fuel (Anthracite, House coal, Wood, etc.)
    → 160 L → SAP10 cylinder_size enum 3 (Medium)
  - "Electricity" + dual/18-hour/24-hour/off-peak meter
    → 210 L → SAP10 cylinder_size enum 4 (Large)
  - otherwise → 110 L → SAP10 cylinder_size enum 2 (Normal)

`_elmhurst_cylinder_size_code` extended with optional water_heating_fuel
+ meter_type kwargs; the single call site at line 4459 threads
`survey.water_heating.water_heating_fuel_type` and
`survey.meters.electricity_meter_type`.

Property 001431 (the heating-systems corpus dwelling) lodges `pcdb 1`
with §14.0 Potterton oil boiler (PCDF 716) + §15.0 "Water Heating Fuel
Type: Heating oil" + §14.2 "Electricity meter type: 18 Hour" — water
fuel is oil (not electric, not solid fuel) → "otherwise" branch → 110 L
→ enum 2 (Normal). `pcdb 1` now cascade-executes (corpus tally 34 → 35
OK / 41 populated).

Extended handover suite at HEAD post-slice: **831 pass, 0 fail**
(was 830 + 1 new AAA test).

Pyright net-zero on touched files (45 → 45 — pre-existing errors
unrelated).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
..
fixtures Slice S0380.52: cert 000565 Elmhurst-only mapper-driven cascade pin + glazing-label coverage 2026-06-01 16:28:47 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
test_elmhurst_end_to_end.py Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-06-01 16:28:46 +00:00
test_elmhurst_extractor.py extract window frame details from elmhurst site notes 🟥 2026-04-27 15:50:25 +00:00
test_end_to_end.py P6.1 follow-on: unbox BuildingPartIdentifier at backend boundaries 2026-05-20 09:58:23 +00:00
test_extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
test_pdf.py rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
test_summary_pdf_mapper_chain.py Slice S0380.127: resolve Elmhurst "No Access" cylinder via RdSAP 10 Table 28 2026-06-01 16:28:48 +00:00