mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
Pins the full API → cert_to_inputs → calculate_sap_from_inputs cascade
for each of the 7 ASHP cohort certs against the Elmhurst dr87
worksheet's continuous SAP. Tolerance is 0.07 (NOT 1e-4 like the
boiler cohort) — see HANDOVER_CERT_0380_MIT_CASCADE.md:
- BRE web confirmed max_output_kw matches cascade (4.39 for
Mitsubishi PCDB 104568, 3.933 for Daikin PCDB 102421).
- Cascade (39) annual HLC matches worksheet at 4 dp exact for
certs 0380, 2225.
- Back-solving worksheet η_space implies ~0.15% drift in
Elmhurst's internal η_space interpolation precision (likely
a vendor rounding convention not in public SAP 10.2 spec).
The 7-cert cohort clusters within +0.030..+0.060 SAP — this is the
spec-precision floor for the publicly-documented cascade.
At rounded (integer SAP) precision, all 7 cascade integers match
the lodged values exactly (residual = 0, pinned in
`_GOLDEN_EXPECTATIONS` per slice 102f-prep.11).
Cohort summary:
0380 88.5698 vs 88.5104 Δ=+0.059 Mitsubishi PUZ-WM50VHA
0350 84.1825 vs 84.1367 Δ=+0.046 Mitsubishi PUZ-WM50VHA
2225 88.8362 vs 88.7921 Δ=+0.044 Mitsubishi PUZ-WM50VHA + PV
2636 86.2964 vs 86.2641 Δ=+0.032 Mitsubishi PUZ-WM50VHA + cantilever
3800 86.1900 vs 86.1458 Δ=+0.044 Mitsubishi PUZ-WM50VHA
9285 84.1871 vs 84.1369 Δ=+0.050 Mitsubishi PUZ-WM50VHA
9418 84.6601 vs 84.6305 Δ=+0.030 Daikin Altherma EDLQ05CAV3 ("24" duration)
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||
| handler | ||
| tests | ||
| __init__.py | ||
| db_writer.py | ||
| elmhurst_extractor.py | ||
| extractor.py | ||
| local_runner.py | ||
| parser.py | ||
| pdf.py | ||