Per RdSAP10 §5.8 final note + Table 14 page 41:
"For drylining including laths and plaster use Rinsulation = 0.17 m²K/W."
Applied additively to the base U-value of an otherwise-uninsulated wall:
U_adjusted = 1 / (1/U_base + 0.17) — rounded to 2 d.p. half-up.
Closed form for the cohort fixture (cavity-as-built age C, U_base=1.5):
1 / (1/1.5 + 0.17) = 1.19522... → 1.20 ✓ matches worksheet
Cert 7700-3362-0922-7022-3563 (Summary_000905.pdf / dr87-0001-000905.pdf)
is an End-Terrace house age C lodging:
- Main wall: CavityWallDensePlasterDenseBlock, Filled Cavity, U=0.70
- Alt wall 1: 14.44 m² Cavity As-Built, Dry-lining: Yes (worksheet
`CavityWallPlasterOnDabsDenseBlock`, U=1.20)
Pre-slice the Elmhurst alt-wall mapper hard-coded `wall_dry_lined="N"`
and the cascade ignored the field everywhere — alt-wall U routed to the
cavity-as-built default (1.50), giving fabric (33) 148.72 W/K vs
worksheet 144.38 (Δ +4.33 W/K = ~+0.44 SAP). Worksheet "SAP value" line
lodges unrounded SAP 63.4425.
Implementation:
1. `AlternativeWall.dry_lined: bool = False` on the Elmhurst surveys
dataclass.
2. Elmhurst extractor reads "Alternative Wall N Dry-lining: Yes/No"
into the new field.
3. `_map_elmhurst_alternative_wall` propagates `wall_dry_lined="Y"`
instead of the hard-coded "N".
4. `u_wall` gains a `dry_lined: bool = False` kwarg and a single
§5.8 adjustment site at the as-built bucket (bucket=0). Insulated
buckets already absorb the dry-lining R via Table 14.
5. `_alt_wall_w_per_k` passes `dry_lined=alt_wall.wall_dry_lined == "Y"`.
Scope is the alt-wall path only — main BPs in the corpus all lodge
`wall_dry_lined="N"` (or the Summary PDF omits the field for the main
wall), so the main-wall call site is untouched. Conservative regression
posture per the user's strict cohort-pin convention.
Cohort-2 outcome (38 certs, Summary path):
exact (<1e-4): 22 → **23** (+1: cert 7700 -0.44 → +4.87e-05)
0.07..0.5: 1 → **0** (-1: cert 7700 closes out)
0.5..1: 1 → 1 (cert 9796 unchanged — MIT precision floor)
RAISES: 0 → 0
Cohort-1 ASHP cohort untouched: all certs lodge wall_dry_lined="N", so
the alt-wall call site short-circuits to the original cascade. Verified
no regressions across the 22 previously-exact cohort-2 certs either.
Pyright net-zero on all 8 touched files (183 → 183).
Tests: 704 → 708 pass (+4 new: u_wall §5.8 adjustment fires
correctly; cavity-as-built unchanged without flag; insulated bucket
unaffected by flag; heat_transmission alt-wall delta = 14.44 × 0.30
W/K; cert 7700 full chain hits worksheet 63.4425 at < 1e-4),
10 expected fails unchanged.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||