Model/tests/domain/sap10_calculator
Khalim Conn-Kowlessar cd5113abf2 fix(tariff): include MVHR fan electricity in the off-peak Grid 2 fan split
SAP 10.2 Table 12a Grid 2 (PDF p.191) bills "Fans for mechanical ventilation
systems" at 0.71 (7-hour) / 0.58 (10-hour), distinct from "All other uses"
(0.90 / 0.80) which covers circulation pumps, flue fans and the solar HW pump.

The cost-split mech-vent kWh (`mev_kwh_for_cost_split`) only summed the
decentralised-MEV (230b) fans, not the (230a) MVHR fan electricity — even
though the total pumps/fans bucket adds both. So an MVHR dwelling on an
off-peak tariff billed its fan electricity at the 0.90/0.80 "all other uses"
rate instead of 0.71/0.58. The comment already said "MEV/MVHR-fan portion";
only the MEV term was wired when MVHR landed. Fixed to mirror both
mechanical-ventilation fan terms summed into the total.

Worksheet-proven on simulated case 50 (000565 semi + MVHR Vent Axia + dual
electric immersion, Unknown meter -> 7-hour via the §12 dual-immersion
trigger): the fan bucket (315.64 kWh, 100% MVHR per worksheet line 230a) was
billing at 14.311 p/kWh (0.90) vs Elmhurst's 12.451 p/kWh (0.71) — +£5.87/yr,
-0.23 SAP. After the fix our existing-dwelling rating reconciles to Elmhurst
EXACTLY: SAP value 38.8426 (=Elmhurst 38.8426 -> 39), total cost £1317.0116
(=Elmhurst £1317.0116 to the penny).

Same `mev_kwh_for_cost_split` feeds the CO2 + PE cascades, so all three split
consistently. 0 corpus impact (all 3 corpus MVHR certs are standard tariff);
gauge unchanged 73.3% / MAE 0.774 / CO2 0.08 / PE 3.4.

Pin: test_mvhr_fan_electricity_bills_at_grid2_fan_fraction_on_off_peak.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 22:16:58 +00:00
..
climate Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
rdsap fix(tariff): include MVHR fan electricity in the off-peak Grid 2 fan split 2026-06-23 22:16:58 +00:00
validation Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
worksheet fix(water-heating): derive combi keep-hot from the PCDB record, default no-keep-hot 2026-06-23 21:22:02 +00:00
__init__.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_bre_worked_examples.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_calculator.py fix(rating): floor the continuous SAP score at 1 (SAP 10.2 §13 / RdSAP 10 §13) 2026-06-19 14:03:13 +00:00
test_pcdb_etl.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_322_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_323_lookup.py feat(pcdb): parse Table 323 (Centralised MEV / MVHR) + Table 329 efficiency IUF 2026-06-23 19:29:17 +00:00
test_pcdb_table_329_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_362_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_postcode_weather.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_real_cert_sap_accuracy.py Pin uprn_10093116336 (full-SAP gas-combi 2-storey semi): engine 83 vs Elmhurst 79 2026-06-17 09:41:29 +00:00
test_table_12.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_table_12a.py feat(tariff): complete §12 Unknown-meter clause — GSHP/WSHP main triggers off-peak (RdSAP 10 PDF p.62) 2026-06-23 10:09:59 +00:00
test_table_13.py fix(water-heating): 18-/24-hour immersion DHW bills 100% low-rate (Table 12a scope) 2026-06-10 22:01:35 +00:00