mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
SAP 10.2 Table 4a (PDF p.166) Cat 7 "Electric storage heaters"
splits the responsiveness R between two sub-tables:
Off-peak tariff:
Slimline storage heaters ... R = 0.2 402
Convector storage heaters ... R = 0.2 403
Slimline + Celect-type control ... R = 0.4 405
Convector + Celect-type ctrl ... R = 0.4 406
24-hour heating tariff:
Slimline storage heaters ... R = 0.4 402
Convector storage heaters ... R = 0.4 403
Slimline + Celect-type control ... R = 0.6 405
Convector + Celect-type ctrl ... R = 0.6 406
Per SAP 10.2 §12.4.3 (PDF p.36) the 18-hour tariff has electricity
at low rate for 18 hours per day with at most 6h of interruption /
2h max each — operationally equivalent to 24-hour for storage-heater
charging. The cascade therefore routes EIGHTEEN_HOUR + TWENTY_FOUR_
HOUR through the 24-hour Table 4a sub-row.
Pre-slice `_responsiveness` keyed on `sap_main_heating_code` only
and returned R=0.2 for code 402 regardless of tariff. The existing
docstring already flagged the gap:
402: 0.20, # Slimline storage heaters (24-hr tariff: 0.40)
... "promote to (sap_code, tariff) lookup when 24-hour fixture
surfaces; until then the off-peak default applies (under-shoots
R for the 24-hour case)."
Per-line walk on electric 5 (sap_main_heating_code=402 +
meter_type="18 Hour"): cascade T_living (87)[Jan] = 20.1213 vs
worksheet 19.6519, (92)[Jan] = 18.6996 vs worksheet 18.2063, (93)
[Jan] = 19.0996 vs worksheet 18.6063 (cascade +0.4933 K throughout
the cascade). Back-solve from worksheet T_living=19.6519 via the
Table 9b Tsc formula:
Tsc(R=0.4) = 0.6 × (21-2) + 0.4 × (4.3 + 0.9933 × 705.4/210.23)
= 11.4 + 0.4 × 7.6325 = 14.4528
ΔT = 21 - 14.4528 = 6.5472
u_sum = 0.5 × 6.5472 × (7² + 8²) / (24 × 11.43) = 1.3481
T_living = 21 - 1.3481 = 19.6519 EXACT match.
Adds:
- `_CONTINUOUS_CHARGING_TARIFFS: frozenset[Tariff]` = {EIGHTEEN_
HOUR, TWENTY_FOUR_HOUR} — the tariffs treated as "24-hour
heating" for Table 4a R selection.
- `_RESPONSIVENESS_24_HOUR_OVERRIDE_BY_SAP_CODE: dict[int, float]`
— the override table for codes 402/403/405/406 (404, 407, 409
keep the same R in both sub-tables).
- `tariff: Optional[Tariff]` parameter to `_responsiveness`, with
the override consulted before the off-peak default.
- Tariff threaded through both call sites of MIT cascade (rating
+ demand paths) via `tariff_from_meter_type`.
Closures electric 5:
ΔSAP −1.1759 → +0.1081 (91% reduction)
Δcost +£27.09 → −£2.49
ΔCO2 +62.72 → +7.30 kg
ΔPE +438.03 → +0.07 kWh (essentially EXACT)
Electric 5 now joins the same residual cluster as electric 3/6/7/8/
9 (+0.09..+0.12 SAP, −£2..−£3 cost, +£7 CO2) — the cluster that
the prior handovers suspected was a shared shave-the-residual gap.
No regressions on the other 24 cohort variants. Extended handover
suite: 903 pass / 0 fail (was 902 — +1 from the new AAA test).
Pyright net-zero (43 → 43).
Σ |ΔSAP_c| across the 25-variant cohort: 2.30 → 1.24 (~46%
reduction from this slice).
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||