Jun-te Kim 7ee33b9ce8 Normalize RdSAP MVHR PCDF index + duct type on the 21.0.0 path
PRD #1385 phase 2. The 21.0.0 mapper dropped mechanical_ventilation_index_number
and mechanical_vent_duct_type, unlike 21.0.1. cert_to_inputs reads both (PCDB
Table 4f/329 heat-recovery/SFP lookup + the Table 329 in-use factor), so an
MVHR/MEV cert on the 21.0.0 path fell back to the SAP default efficiency.

Mirrors 21.0.1 exactly -- only the two fields it actually maps. The other four
mechanical_vent_duct_* schema fields have no mapper OR calculator consumer even
on 21.0.1 (verified), so they're deliberately left alone rather than populating
dead domain fields.

Verification: new test 1 passed (harvested 21.0.0 sample lodges index=12,
duct_type=3); corpus 6002 passed; SAP-accuracy regressions pass; pyright
unchanged (39 -> 39).