Model/docs
Khalim Conn-Kowlessar d4c090fc7c Slice 27b: §3 element-area rounding to 2 d.p. per RdSAP10 §15 (p.66)
Spec text (RdSAP 10 §15, p.66): "For consistency of application, after
expanding the RdSAP data into SAP data using the rules in this Appendix,
the data are rounded before being passed to the SAP calculator. The
rounding rules are: U-values: 2 d.p. / All element areas (gross)
including window areas and conservatory wall area: 2 d.p. / [...]"

Applied 2-d.p. rounding to every per-element gross area inside
heat_transmission_from_cert: gross_wall + party_wall (in _part_geometry),
window total area, door area, top_floor (roof) area, ground_floor area,
roof-window area, alt-wall area, RR-detailed-surface area. U-values
already came from table lookups at 2 d.p.

§3 cascade pins (LINE_31/33/36/37) now close at abs=1e-4 for 5 of 6
fixtures. 000487 remains failing on the RR defect (slice 25).

Scoreboard:
  section_cascade_pins: 151 → 170 PASS (+19)
  e2e SapResult:        27 →  29 PASS (+2)

Per-fixture §3 status:
  field    | 474 | 477 | 480 | 487 | 490 | 516
  LINE_31  |  ✓  |  ✓  |  ✓  |  ✗  |  ✓  |  ✓
  LINE_33  |  ✓  |  ✓  |  ✓  |  ✗  |  ✓  |  ✓
  LINE_36  |  ✓  |  ✓  |  ✓  |  ✗  |  ✓  |  ✓
  LINE_37  |  ✓  |  ✓  |  ✓  |  ✗  |  ✓  |  ✓

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-05-23 09:13:57 +00:00
..
adr docs: handover for Table 3c two-profile combi loss → close 4 Elmhurst fixtures 2026-05-22 12:14:00 +00:00
sap-spec Slice 27b: §3 element-area rounding to 2 d.p. per RdSAP10 §15 (p.66) 2026-05-23 09:13:57 +00:00