Khalim Conn-Kowlessar d4d2b222fc feat(conservatory): §6.1 fabric cascade (27/27a/28a + TFA/volume)
Wire the non-separated conservatory into the §3 heat-transmission +
§1 dimensions cascade per RdSAP 10 §6.1 (PDF p.49) + Table 25 (p.51):

  "The floor area and volume of a non-separated conservatory are added to
   the total floor area and volume of the dwelling. Its roof area is taken
   as its floor area divided by cos(20°), and wall area is taken as the
   product of its exposed perimeter and its height. ... The conservatory
   walls and roof are taken as fully glazed ... Glazed walls are taken as
   windows, glazed roof as rooflight."

New `worksheet/conservatory.py` derives the geometry:
  - height from the equivalent storey count (§6.1: 1 storey → ground-floor
    room height; 1½ → ground + 0.25 + 0.5×first; etc.);
  - glazed WALL → window (27) at Table 25 U (double 3.1 / single 4.8) with
    the §3.2 curtain resistance (R=0.04) → U_eff 2.758;
  - glazed ROOF → rooflight (27a) at Table 25 roof U (double 3.4 / single
    5.3) + curtain → U_eff 2.993;
  - FLOOR → (28a) via BS EN ISO 13370 as an uninsulated SOLID ground floor
    with 300 mm walls (§5.12, spec p.43), exposed perimeter = glazed
    perimeter → U 0.89;
  - glazed wall + roof + floor areas join (31)/(36); the fully-glazed
    structure walls/roof add nothing (the glazing IS the window/rooflight).

`dimensions_from_cert` adds the conservatory floor area to TFA (4) and
floor area × height to volume (5) (feeds ventilation (8)), without making
it a storey (avg storey height for §2 infiltration is unchanged).

Pinned against the simulated case-44 P960 §3 at abs=1e-4 — every line ref
EXACT: (4) 95.3800, (5) 257.1630, (27) 96.1169, (27a) 38.2201, (28a)
21.4164, (29a) 35.5852, (30) 7.4688, (31) 294.2900, (33) 207.3274,
(36) 23.5432. The remaining whole-dwelling SAP/CO2 gap is the §6 solar
gains, closed in the next slice. Worksheet harness stays 47/47 0-raised.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 15:59:26 +00:00
..
applications put db engine construction inside handler to avoid import errors in test 2026-06-09 15:18:42 +00:00
datatypes fix(mapper): map Elmhurst "Value known" cylinder to measured volume (code 6) 2026-06-15 23:57:25 +00:00
domain feat(conservatory): §6.1 fabric cascade (27/27a/28a + TFA/volume) 2026-06-16 15:59:26 +00:00
harness test(harness): re-pin golden-cert plans to the gain-maximising packages 2026-06-15 13:57:27 +00:00
infrastructure test(corpus): ratchet SAP ceiling 0.99->0.97 (§3.9.2 Type-2 RR) 2026-06-16 15:01:34 +00:00
magic_plan Migrate all MagicPlan tests to single new-format fixture 🟪 2026-06-05 12:59:56 +00:00
orchestration Merge pull request #1217 from Hestia-Homes/feature/per-cert-mapper-validation 2026-06-15 15:03:05 +01:00
repositories Merge branch 'main' of https://github.com/Hestia-Homes/Model into feature/junte+khalim 2026-06-12 13:45:30 +00:00
scripts fix terraform error and pass handler bool for dry runs 2026-06-15 14:06:54 +00:00
utilities added floats helper 2026-06-12 14:28:41 +00:00
__init__.py added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
conftest.py Audit generator populates XLSX, uploads to S3, and records UploadedFile row 🟪 2026-06-09 12:05:55 +00:00