Cert 0330 (mid-terrace boiler, Summary_000897.pdf) Summary path was at
Δ +0.4667 SAP vs worksheet 61.5993 because Ext1's flat roof fell through
`_ROOF_BY_AGE` (Table 18 column (1), pitched-roof "between joists"
defaults) to 0.40 W/m²K for age D — the spec value is 2.30 W/m²K from
column (3) "Flat roof" (RdSAP 10 spec page 45).
RdSAP 10 §5.11 Table 18 column (3) verbatim:
Age A,B,C,D → 2.30; E → 1.50; F → 0.68; G → 0.40; H,I → 0.35;
J,K → 0.25; L → 0.18; M → 0.15.
Footnote (a): "If the roof insulation is 'none' use U = 2.3 (all roof
types, except for thatched roofs)" — confirms the col-3 entries for
old ages are the uninsulated row, applied because cert 0330's Ext1
lodges "Flat" construction with no measured insulation thickness.
Changes:
- `_FLAT_ROOF_BY_AGE` added in rdsap_uvalues.py
- `u_roof` gains `is_flat_roof: bool = False` parameter
- `heat_transmission_from_cert` detects flat roofs from
`part.roof_construction_type` ("flat" substring) and routes through
the new column.
Effect on baseline:
- cert 0330 Summary chain test: RED Δ+0.4667 → GREEN at 1e-4 (worksheet
total fabric heat loss 237.7549 W/K matches cascade to 4 d.p.)
- cert 001479 Layer 4 chain test: unchanged (Main pitched, no flat
components)
- cohort certs 000477/000516: unchanged (no flat roofs)
- golden cert 0300-2747-7640-2526-2135: SAP residual +1 → 0 (improved),
Ext1 is genuinely flat; pe/co2 residuals re-pinned. The dwelling has
the same Main-pitched + Ext1-flat shape as cert 0330; same fix.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||