Khalim Conn-Kowlessar 68aa80c174 feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned
Slice 1 of solid-wall insulation. BuildingPartOverlay gains a
wall_insulation_thickness field; the generic applicator already folds it onto
SapBuildingPart by name. With wall_insulation_type=1 (EWI) / 3 (IWI) + 100 mm,
the calculator derives the post-insulation U-value (§5.8 documentary path,
λ=0.04 default) — and for IWI also lowers the thermal-mass parameter. Two new
Elmhurst before/after cascade pins (solid-brick EWI + IWI, cert 001431)
reproduce the re-lodged after at abs(diff) <= 1e-4 across SAP/CO2/PE.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-04 15:11:26 +00:00
..
cavity_wall_001431_after.pdf test(modelling): Elmhurst before/after cascade pin for cavity wall (#1154) 2026-06-03 09:36:53 +00:00
cavity_wall_001431_before.pdf test(modelling): Elmhurst before/after cascade pin for cavity wall (#1154) 2026-06-03 09:36:53 +00:00
loft_001431_after.pdf feat(modelling): loft overlay 270→300 mm + Elmhurst cascade pin (#1158) 2026-06-03 09:39:21 +00:00
loft_001431_before.pdf feat(modelling): loft overlay 270→300 mm + Elmhurst cascade pin (#1158) 2026-06-03 09:39:21 +00:00
solid_brick_ewi_001431_after.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_brick_ewi_001431_before.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_brick_iwi_001431_after.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_brick_iwi_001431_before.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_floor_001431_after.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00
solid_floor_001431_before.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00
suspended_floor_001431_after.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00
suspended_floor_001431_before.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00