New module `domain/sap10_calculator/worksheet/appendix_h_solar.py`
implements line refs (H10), (H11), (H14)..(H16), (H17)..(H24) for the
hot-water solar contribution path. The space-heating path (H25)..(H29)
is deferred until a fixture exercises it — cert 000565 lodges solar
HW only (worksheet line 414 H29=0 across all months).
Algorithm per SAP 10.2 specification §Appendix H pages 74-78
(14-03-2025 revision). The monthly procedure follows EN 15316-4-3:2017:
the collector + cylinder + demand parameters feed dimensionless X and
Y ratios into Equation H1 with Table H3 (p.78) correlation factors:
Q_s,w = (Ca·Y + Cb·X + Cc·Y² + Cd·X² + Ce·Y³ + Cf·X³) × (H17)m
clamped to [0, (H17)m] per spec p.76. Cert 000565 worksheet line 415
shows total Q_s,w = 281.3478 kWh/year delivered to HW from a 3 m²
flat-plate collector + 53 L dedicated solar storage in a 160 L
combined cylinder, W orientation, 30° pitch, Thames Valley region.
Helpers implemented:
- `overall_heat_loss_coefficient_h10` — 5 + 0.5×(H1) or test-cert
- `loop_heat_loss_coefficient_h11` — (H3) + 40·(H4) + (H10)/(H1)
- `effective_solar_volume_h14` — separate / combined cylinder
- `reference_volume_h15` — 75 × (H1)
- `storage_tank_correction_coefficient_h16` — [(H15)/(H14)]^0.25
- `hot_water_demand_monthly_h17_kwh` — (62)m − (63a)m
- `proportion_solar_to_hot_water_monthly_h18` — HW-only/SH-only/blend
- `hot_water_reference_temperature_h20_c` — 55 + 3.86·Tcold − 1.32·Te
- `hot_water_reference_temperature_difference_h21_c` — (H20) − (96)
- `hot_water_factor_x_monthly_h22` — clamp [0, 18]
- `hot_water_factor_y_monthly_h23` — clamp ≥ 0
- `heat_delivered_to_hot_water_monthly_h24_kwh` — Equation H1 + clamp
[0, (H17)m]
18 unit tests cover:
- Spec-default vs test-certificate (H10)
- Cert 000565 worksheet pinned (H11) ≈ 6.5667 (line 407)
- Cert 000565 worksheet pinned (H14) = 85.1 (line 410)
- Cert 000565 worksheet pinned (H15) = 225 (line 411)
- Cert 000565 worksheet pinned (H16) ≈ 1.2752 (line 412)
- Separate-tank vs combined-cylinder branches of (H14)
- All three branches of (H18) (HW-only, SH-only, blend formula)
- (H20)/(H21) spec formulas verbatim
- (H22) zero-demand short-circuit + upper clamp at 18
- (H23) negative-input lower clamp at 0
- (H24) Equation H1 polynomial with Table H3 factors
- (H24) demand-cap clamp when Y dominates positive
- (H24) zero-floor clamp when X dominates negative
Scope EXCLUDES (deferred to follow-on slices):
- Appendix U §U3.3 monthly solar radiation lookup for the collector's
orientation/tilt → (H7)m → (H9)m
- Solar SH path (H25-H29)
- Appendix H §H2 primary-loss reduction Table H4
- EpcPropertyData solar collector field schema additions
- Elmhurst + API extractor / mapper updates
- Cascade integration via `water_heating_from_cert.solar_monthly_kwh`
Pyright: 0 errors on both touched files. 275 pass + 9 expected 000565
cascade-gap fails on the handover test suite (unchanged from S0380.65).
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||