mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
Probed all three variants (electric 3, oil 1, solid fuel 2) in this thread. Each has a different driver despite the matching magnitude: - electric 3: §9 useful-demand calc for ctrl=3 storage heaters - oil 1: HW efficiency for Table 4b oil boiler (cascade 86% vs ws ~65%) - solid fuel 2: HW kWh lodged in different line ref (re-probe needed) Tested combined-R hypothesis (effective_R = (1-frac)·R_main + frac·R_sec per SAP 10.2 §9b) — the cascade currently DOES NOT pass secondary_fraction to mean_internal_temperature_monthly, so effective_R = R_main. Monkey- patching to inject combined R REGRESSES electric 3 (+2.55 → +3.17) because raising R lowers cascade demand — opposite of needed direction. Recommends taking the three variants as separate per-variant slices. Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com> |
||
|---|---|---|
| .. | ||
| addresses | ||
| data_transformation | ||
| epc | ||
| sap10_calculator | ||
| sap10_ml | ||
| tasks | ||
| postcode.py | ||