mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
The §7 mean-internal-temperature cascade hardcoded the thermal mass parameter
(TMP) to 250 kJ/m²K at all 5 call sites, ignoring construction. RdSAP 10
§5.16 Table 22 (PDF p.48) makes TMP construction-dependent:
100 kJ/m²K — timber frame, cob, park home (regardless of internal
insulation); OR masonry (stone/solid brick/cavity/system
built) WITH internal insulation.
250 kJ/m²K — masonry WITHOUT internal insulation.
A too-high TMP inflates the §7 time constant τ = Cm/(3.6·H) (e.g. 40 h vs
16 h), under-cuts the temperature reduction between heating periods, and
over-states mean internal temperature → over-states space heating.
`_thermal_mass_parameter_kj_per_m2_k(epc)` classifies the MAIN building's
wall via the RdSAP `wall_construction` codes (5/7/8 = timber/cob/park) and
`wall_insulation_type` codes (3/7 = internal); unknown/curtain fall back to
the masonry 250 (no regression on unlisted classes). 17-case parametrised
test covers every Table 22 branch.
Diagnosis (per-line walk vs the user-simulated 001431 worksheet, same
archetype as golden cert 6035): fabric (26-37), internal gains (73), climate
(96)m and HTC (39) all EXACT; the entire +8.78 PE / -1.76 SAP gap was §7 MIT
(92) +0.71 °C, traced to TMP 250 vs Table 22's 100 (solid brick WITH internal
insulation). Fix closes the simulated case to 1e-4 on PE and CO2.
Blast radius: only golden cert 6035 re-pins (solid brick + internal
insulation) — SAP resid -6 → -2, PE +46.42 → +19.16, CO2 +1.07 → +0.42. The
47 dr87 cohort, 6 U985 fixtures and 41-variant heating corpus are all
masonry-no-internal → TMP unchanged at 250, all still pass. 2290 pass
(+17 new), 0 fail; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||
| applications | ||
| domain | ||
| infrastructure | ||
| orchestration | ||
| repositories | ||
| utilities | ||
| __init__.py | ||
| conftest.py | ||
| test_lambda_packaging.py | ||