Model/backend/documents_parser/tests/fixtures
Khalim Conn-Kowlessar 27375d93a4 fix(u-value): solid brick as-built U by thickness — §5.7 Table 13
A 440 mm (>420 mm) solid brick AS-BUILT wall computed U = 1.70 (the
220 mm bucket default) instead of the RdSAP-correct 1.10. The §5.7
Table 13 thickness path only fired for *insulated* brick (external/
internal + thickness > 0); the as-built case fell through to the
Table 6 cavity/solid age-band default.

Spec: RdSAP 10 Specification (9th June 2025), §5.7 "U-values for
uninsulated brick walls, age bands A to E", Table 13 (PDF p.40):
  ≤200 mm → 2.5, 200–280 mm → 1.7, 280–420 mm → 1.4, >420 mm → 1.1.
Table 6 footnote (b) on the "Solid brick as built" row (PDF p.40):
"Or from 5.7 if wall thickness is other than 200mm to 280mm" — the
thickness table supersedes the flat 1.7 default whenever a documentary
wall thickness is lodged (200–280 mm gives 1.7 either way). The §5.8 /
Table 14 dry-lining R is added on top only when the wall is dry-lined,
per the §5.7 closing sentence.

Validated against the user-generated Elmhurst worksheet "simulated
case 21" (replica of API cert 2818-3053-3203-2655-9204: mid-terrace,
age band B, solid brick as-built 440 mm, room-in-roof). New §3 cascade
pin `test_section_3_wall_u_by_thickness_case21_match_pdf` routes the
Summary through the real extractor + mapper and pins:
  (31) 155.1000, (33) 175.6208, (36) 23.2650, (37) 198.8858 — all 1e-4.
External walls Main U → 1.1000; Sheltered RR gable → 1/(1/1.10+0.5) =
0.71 (was 0.92). Pinned on §3 only (case-6 precedent): its code-908
instantaneous multi-point gas water heater has a separate §4 (219) gap.

Cross-check: sim case 20 (220 mm) stays at 1.70 — unchanged.

API SAP accuracy (scripts/eval_api_sap_accuracy.py, 896 computed certs):
% |err| < 0.5 SAP vs lodged: 42.6% → 43.8%; mean |err| 2.045 → 2.010.

Regression: tests/domain/sap10_calculator/ (1861), backend/
documents_parser/tests/ (574), datatypes/epc/ + rdsap golden fixtures
all green (pre-existing test_total_floor_area excepted). pyright strict
net-zero. No solid-brick fixture pin shifted (200–280 mm unchanged).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 14:40:06 +00:00
..
elmhurst_site_notes_1_text.json elmhurst site notes fixture 2026-04-24 13:09:30 +00:00
elmhurst_site_notes_2_text.json extract window frame details from elmhurst site notes 🟥 2026-04-27 15:50:25 +00:00
ElmhurstSiteNotes.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
ElmhurstSiteNotes_2.pdf extract window frame details from elmhurst site notes 🟥 2026-04-27 15:50:25 +00:00
pashub_site_notes_1_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_2_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_3_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_4_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_5_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_6_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_7_text.json Extract address when Property photo element is missing from PDF 🟩 2026-04-30 16:25:41 +00:00
PasHubSiteNotes_1.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_2.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_3.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_4.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_5.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_6.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_7.pdf Extract address when Property photo element is missing from PDF 🟩 2026-04-30 16:25:41 +00:00
Summary_000474.pdf Scaffold: end-to-end Summary→EpcPropertyData chain test for 000474 (xfail) 2026-05-24 17:40:06 +00:00
Summary_000477.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000480.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000487.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000490.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000516.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000565.pdf Slice S0380.52: cert 000565 Elmhurst-only mapper-driven cascade pin + glazing-label coverage 2026-05-28 22:03:52 +00:00
Summary_000784.pdf chore: stage cert 9501 fixtures (second boiler validation cert) 2026-05-26 18:53:08 +00:00
Summary_000884.pdf Slice S0380.16: add 'Normal' → cylinder_size=2 (110 L) for cohort 2 2026-05-27 22:44:02 +00:00
Summary_000888.pdf Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
Summary_000889.pdf Slice S0380.16: add 'Normal' → cylinder_size=2 (110 L) for cohort 2 2026-05-27 22:44:02 +00:00
Summary_000890.pdf Slice S0380.19: count Elmhurst shower outlets by type (no more hardcoded 1) 2026-05-28 07:16:32 +00:00
Summary_000897.pdf chore: stage cert 0330 fixtures (boiler pilot) 2026-05-26 17:37:14 +00:00
Summary_000898.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000899.pdf chore: stage cert 0380 fixtures (HP pilot — deferred workstream) 2026-05-26 17:37:34 +00:00
Summary_000900.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000901.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000902.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000903.pdf Slice S0380.9: multi-array PV support + close cert 0350 to ASHP spec floor 2026-05-27 20:44:13 +00:00
Summary_000904.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000910.pdf Slice S0380.18: u_party_wall flat default per RdSAP10 Table 15 footnote* 2026-05-27 23:24:58 +00:00
Summary_001431_6035.pdf S0380.195: pin sim case 4 (6035 floor geometry) e2e at 1e-4 — 6035 +19 PE is lodged divergence 2026-06-03 09:56:39 +00:00
Summary_001431_case5.pdf S0380.197: simulated case 5 e2e fixture — detached sandstone RR validates S0380.196 (RdSAP 10 §3.9.1 + Table 4 p.22) 2026-06-03 11:41:16 +00:00
Summary_001431_case6.pdf S0380.199: site-notes "Roof of Room" windows → roof windows (cross-mapper parity with S0380.198) 2026-06-03 12:46:18 +00:00
Summary_001431_case7.pdf S0380.208: case 7 combi e2e fixture — condensing-oil-combi path validated exact 2026-06-03 17:57:22 +00:00
Summary_001431_case20.pdf fix(extractor): re-join §11 windows whose Area cell split onto its own line 2026-06-06 10:35:21 +00:00
Summary_001431_case21.pdf fix(u-value): solid brick as-built U by thickness — §5.7 Table 13 2026-06-06 14:40:06 +00:00
Summary_001431_double_glazing.pdf S0380.236: extension party-wall type read independently of "As Main Wall" 2026-06-05 09:19:43 +00:00
Summary_001431_gas_combi.pdf S0380.191: pin simulated 001431 gas-combi end-to-end at 1e-4 (e2e harness) 2026-06-02 22:44:32 +00:00
Summary_001431_rr8w.pdf S0380.194: pin sim case 3 (near-exact 6035 replica) e2e at 1e-4 2026-06-03 09:46:56 +00:00
Summary_001431_rr_ext.pdf S0380.193: suspended-floor (12) sealed rule fires only on a SUPPLIED U-value 2026-06-03 09:16:25 +00:00
Summary_001479.pdf Slice 54: Elmhurst mapper sets extensions_count from len(survey.extensions) 2026-05-24 22:15:47 +00:00