Model/backend/documents_parser
Khalim Conn-Kowlessar fe3bf4eaed fix(ventilation): read Blower Door AP50 pressure test (Summary)
SAP 10.2 §2 (17)-(18): a measured/design air permeability at 50 Pa from a
Blower Door test routes infiltration via `(18) = AP50/20 + (8)`, in
preference to the components-based (16) estimate. The Elmhurst extractor
read only the AP4 ("Pulse") column of §12.2, so a Blower Door result
(§12.2 "Pressure Test Result (AP50)") fell through to the structural-
infiltration default — over-counting ventilation heat loss.

Surfaced by simulated case 44 (AP50 4.50): effective air change rate was
0.81 vs the worksheet's 0.58 (+38% ventilation loss). The cascade already
supports `air_permeability_ap50` (preferred over AP4); this wires the read
end to end (extractor → ElmhurstSiteNotes → SapVentilation → cert_to_inputs).

Pinned against the case-44 P960 §2 at abs=1e-4: (18) infiltration 0.3417
(= 4.5/20 + 0.1167) and (25) Jan effective ach 0.5812. Worksheet harness
stays 47/47 0-raised.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 23:18:17 +00:00
..
handler address JTK review comments 2026-04-20 15:11:17 +00:00
tests feat(conservatory): §6.1 fabric cascade (27/27a/28a + TFA/volume) 2026-06-16 15:59:26 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
db_writer.py include updating epc_property_data to pashub to ara workflow 2026-04-29 09:55:14 +00:00
elmhurst_extractor.py fix(ventilation): read Blower Door AP50 pressure test (Summary) 2026-06-16 23:18:17 +00:00
extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
local_runner.py update local runner to work for elmhurst 2026-04-24 14:01:36 +00:00
parser.py load ecmk site notes to db 2026-04-29 11:20:47 +00:00
pdf.py update local runner to work for elmhurst 2026-04-24 14:01:36 +00:00