"""The Landlord-Override main-heating-system → heating Simulation Overlay mapping.
A main-heating-system value resolves to the SAP `sap_main_heating_code` the
calculator reads from the primary system; the overlay is whole-dwelling.
"""
from __future__ import annotations
import logging
import pytest
from domain.epc.property_overrides.main_heating_system_type import MainHeatingSystemType
from domain.epc.property_overlays.main_fuel_overlay import fuel_overlay_for
from domain.epc.property_overlays.main_heating_system_overlay import (
_ASSUMED_DUAL_METER_CODES,
_MAIN_HEATING_CODES,
_METER_AGNOSTIC_CODES,
main_heating_overlay_for,
)
from domain.epc.property_overlays.water_heating_overlay import (
water_heating_overlay_for,
)
from domain.modelling.scoring.overlay_applicator import apply_simulations
from tests.domain.sap10_calculator.worksheet._elmhurst_worksheet_000490 import (
build_epc,
)
def test_gas_combi_overlays_the_primary_heating_code() -> None:
# Act
simulation = main_heating_overlay_for("Gas boiler, combi", 0)
# Assert — condensing combi is SAP Table 4b code 104.
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == 104
def test_electric_room_heaters_overlay_the_direct_acting_room_heater_code() -> None:
# Act — panel/convector/radiant direct-acting electric room heaters
simulation = main_heating_overlay_for("Electric room heaters", 0)
# Assert — SAP Table 4a code 691, NOT convector storage (403).
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == 691
def test_electric_room_heaters_assume_a_dual_economy7_meter() -> None:
# A dwelling on electric room heaters is all-electric and realistically
# billed on Economy 7 (its immersion hot water charges overnight; §12 Rule 3
# gives the room heaters a 10-hour off-peak window). When the landlord names
# only the system, the coherent meter to assume is Dual — the §12 dispatch
# then applies the realistic high/low split, not a single-rate over-penalty.
simulation = main_heating_overlay_for("Electric room heaters", 0)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.meter_type == "Dual"
def test_electric_room_heaters_overlay_the_room_heater_category() -> None:
# A landlord "Electric room heaters" override replaces the lodged system, so
# the overlay must stamp the room-heater heating category (SAP Table 4a
# Category 10). Leaving it unset lets a replaced storage heater's category 7
# survive onto the effective cert, which the SAP 10.2 Table 12a resolver
# (keyed on category) mis-reads as off-peak storage and bills the peaky room
# heaters at the all-night low rate.
# Act
simulation = main_heating_overlay_for("Electric room heaters", 0)
# Assert — SAP Table 4a Category 10 (Room heaters).
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_category == 10
def test_electric_room_heaters_overlay_the_room_heater_charge_control() -> None:
# A system-replacing override must stamp its own control, not inherit the
# replaced system's. Electric room heaters take the Table 4e Group 6
# room-heater control 2601 (+0.3 C, the conservative no-thermostat default,
# matching the gas/oil/solid room heaters). Leaving it unset lets a replaced
# storage heater's manual charge control 2401 (+0.7 C) survive and over-warm
# the modelled dwelling.
# Act
simulation = main_heating_overlay_for("Electric room heaters", 0)
# Assert — SAP Table 4e Group 6 room-heater control.
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_control == 2601
def test_overlay_raises_on_an_incomplete_companion_set(
monkeypatch: pytest.MonkeyPatch,
) -> None:
# Every real archetype resolves a complete companion set, so the
# log-and-continue mitigation has no remaining population and the
# ADR-0048 end-state applies: an incomplete set FAILS LOUDLY instead of
# shipping a silently-incoherent cert (ADR-0053, #1444 Part C). Simulated
# with a hypothetical warm-air heat-pump archetype (SAP 521 — category 4
# but its Table 4e Group 5 control is deliberately unmapped): a future
# archetype cannot land without choosing its companions.
from domain.epc.property_overlays import main_heating_system_overlay as mod
monkeypatch.setitem(mod._MAIN_HEATING_CODES, "Warm-air heat pump", 521)
# Act / Assert — the raise names the archetype.
with pytest.raises(ValueError, match="Warm-air heat pump"):
main_heating_overlay_for("Warm-air heat pump", 0)
@pytest.mark.parametrize(
"main_heating_value",
["Community heating, boilers", "Community heating, CHP and boilers"],
)
def test_community_heating_drags_the_default_group_3_control(
main_heating_value: str,
) -> None:
# The landlord names the scheme, not its control or charging arrangement.
# The Table 4e Group 3 default is 2313 ("flat rate charging, room
# thermostat and TRVs"): community schemes skew modern and the portfolio's
# own lodged community certs are overwhelmingly thermostatted (modal 2306;
# none lodge 2301), so the KIT axis concedes to the evidence — while the
# CHARGING axis stays flat-rate (space 1.05 / DHW 1.05): the billing
# arrangement is scheme paperwork an override genuinely cannot see, so
# usage-linked (1.0/1.0) is never assumed (ADR-0053, decided with Khalim).
# Leaving the control unset inherits the replaced system's instead (the
# ADR-0048 bug class).
# Act
simulation = main_heating_overlay_for(main_heating_value, 0)
# Assert — SAP Table 4e Group 3 default heat-network control.
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_control == 2313
def test_air_source_heat_pump_drags_the_conservative_group_2_control() -> None:
# The landlord names the system, not its control, so the overlay assumes
# the conservative Table 4e Group 2 default: 2201 ("no time or thermostatic
# control", +0.3 C — the largest Group 2 adjustment, so an unobserved
# control is never over-credited; the heat-pump mirror of storage 2401 /
# boiler 2101). Deliberately NOT the ASHP Measure's 2210 zone control —
# a measure designs a modern end-state (ADR-0024); an override describes an
# existing pump (ADR-0053).
# Act
simulation = main_heating_overlay_for("Air source heat pump", 0)
# Assert — SAP Table 4e Group 2 conservative heat-pump control.
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_control == 2201
def test_complete_room_heater_overlay_does_not_log_a_companion_gap(
caplog: pytest.LogCaptureFixture,
) -> None:
# Electric room heaters now resolve a full companion set (category 10 +
# control 2601), so the overlay must NOT log an incomplete-companion gap —
# guarding that the fix keeps the set complete.
# Act
with caplog.at_level(logging.ERROR):
main_heating_overlay_for("Electric room heaters", 0)
# Assert
assert "incomplete companion set" not in caplog.text
@pytest.mark.parametrize(
("main_heating_value", "code"),
[
("Gas boiler, regular", 102),
("Gas CPSU", 120),
("Electric storage heaters, fan", 404),
("Direct-acting electric", 191),
],
)
def test_heating_archetypes_decode_to_their_sap_codes(
main_heating_value: str, code: int
) -> None:
# Act
simulation = main_heating_overlay_for(main_heating_value, 0)
# Assert
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == code
@pytest.mark.parametrize(
("main_heating_value", "code"),
[
# Solid-fuel room heaters the LLM funnelled into "Gas CPSU" (120, mains
# gas). SAP Table 4a: 631 open fire, 632 open fire + back boiler, 634
# closed room heater + boiler (ADR-0045).
("Solid fuel room heater, open fire", 631),
("Solid fuel room heater, open fire with back boiler", 632),
("Solid fuel room heater, closed with boiler", 634),
],
)
def test_solid_fuel_room_heaters_decode_off_gas_cpsu(
main_heating_value: str, code: int
) -> None:
# Act
simulation = main_heating_overlay_for(main_heating_value, 0)
# Assert — its own solid-fuel code, not mains-gas CPSU (120).
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == code
def test_electric_boiler_decodes_to_191_and_drags_electricity() -> None:
# An "A rated NA" boiler (all-electric per its main_fuel override) was funnelled
# into Gas CPSU (120, mains gas). It is a direct-acting electric boiler (SAP 191)
# and unambiguously electric, so the archetype drags electricity (29) — never
# leaving a mains-gas fuel to bleed through (ADR-0045).
simulation = main_heating_overlay_for("Electric boiler", 0)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == 191
assert simulation.heating.main_fuel_type == 29
def test_electric_cpsu_decodes_to_192_electric_on_an_off_peak_meter() -> None:
# An electric "Boiler: A rated CPSU" was funnelled into mains-gas Gas CPSU
# (120). Electric CPSU is SAP Table 4a 192, electric (29), charging overnight on
# a Dual off-peak meter (§12 Rule 1, 10-hour) — ADR-0045.
simulation = main_heating_overlay_for("Electric CPSU", 0)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == 192
assert simulation.heating.main_fuel_type == 29
assert simulation.heating.meter_type == "Dual"
@pytest.mark.parametrize(
("main_heating_value", "code"),
[
# Electric underfloor funnelled into Direct-acting (191) / old storage (401)
# for want of the dedicated SAP Table 4a underfloor codes (ADR-0046).
("Electric underfloor, in concrete slab (off-peak)", 421),
("Electric underfloor, integrated storage and direct-acting", 422),
("Electric underfloor, in screed above insulation", 424),
],
)
def test_electric_underfloor_decodes_to_its_own_code_dragging_electricity(
main_heating_value: str, code: int
) -> None:
# Act
simulation = main_heating_overlay_for(main_heating_value, 0)
# Assert — its own underfloor code, electric (29).
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == code
assert simulation.heating.main_fuel_type == 29
@pytest.mark.parametrize(
"main_heating_value",
[
# "off-peak only" / "off peak" positively claim off-peak.
"Electric underfloor, in concrete slab (off-peak)",
"Electric underfloor, integrated storage and direct-acting",
],
)
def test_off_peak_underfloor_asserts_a_dual_meter(main_heating_value: str) -> None:
# Act
simulation = main_heating_overlay_for(main_heating_value, 0)
# Assert — an off-peak underfloor must not bill overnight heat at the peak rate.
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.meter_type == "Dual"
@pytest.mark.parametrize(
"main_heating_value",
[
"Electric underfloor, in concrete slab (off-peak)",
"Electric underfloor, integrated storage and direct-acting",
"Electric underfloor, in screed above insulation",
],
)
def test_electric_underfloor_overlays_the_underfloor_category(
main_heating_value: str,
) -> None:
# A system-replacing override must stamp the underfloor heating category
# (SAP Table 4a Category 8). Leaving it unset lets the replaced system's
# category survive onto the effective cert — property 711795's community
# heating (category 6) survived an underfloor override, so the heating
# generator read the dwelling as a heat network and offered no heating
# upgrade at all, and the baseline mis-rated 51 vs 67 (ADR-0050).
# Act
simulation = main_heating_overlay_for(main_heating_value, 0)
# Assert — SAP Table 4a Category 8 (Electric underfloor heating).
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_category == 8
@pytest.mark.parametrize(
"main_heating_value",
[
"Electric underfloor, in concrete slab (off-peak)",
"Electric underfloor, integrated storage and direct-acting",
"Electric underfloor, in screed above insulation",
],
)
def test_electric_underfloor_drags_the_conservative_group_7_control(
main_heating_value: str,
) -> None:
# The landlord names the system, not its control, so the overlay assumes the
# conservative Table 4e Group 7 default: 2701 ("no time or thermostatic
# control", +0.3 C — the largest adjustment in the group, so an unobserved
# control is never over-credited). Mirrors storage-manual 2401 / room-heater
# 2601; also overwrites a stale control inherited from the replaced system
# (711795 kept a community control 2311) — ADR-0050.
# Act
simulation = main_heating_overlay_for(main_heating_value, 0)
# Assert — SAP Table 4e Group 7 conservative underfloor control.
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_control == 2701
@pytest.mark.parametrize(
"main_heating_value",
[
"Electric underfloor, in concrete slab (off-peak)",
"Electric underfloor, integrated storage and direct-acting",
"Electric underfloor, in screed above insulation",
],
)
def test_complete_underfloor_overlay_does_not_log_a_companion_gap(
main_heating_value: str, caplog: pytest.LogCaptureFixture
) -> None:
# Electric underfloor now resolves a full companion set (category 8 +
# control 2701, ADR-0050), so the overlay must NOT log an
# incomplete-companion gap — guarding that the set stays complete.
# Act
with caplog.at_level(logging.ERROR):
main_heating_overlay_for(main_heating_value, 0)
# Assert
assert "incomplete companion set" not in caplog.text
def test_screed_underfloor_defers_the_meter_to_the_cert() -> None:
# "In screed above insulation (standard or off peak)" is tariff-ambiguous (81%
# of the corpus lodge off-peak), so the archetype cannot know the meter — it
# leaves meter_type unset so the cert's lodged meter stands (ADR-0046).
simulation = main_heating_overlay_for(
"Electric underfloor, in screed above insulation", 0
)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.meter_type is None
@pytest.mark.parametrize(
("main_heating_value", "code"),
[
("Electric storage heaters, old", 401),
("Electric storage heaters, slimline", 402),
("Electric storage heaters, convector", 403),
],
)
def test_storage_heater_subtypes_decode_to_their_codes(
main_heating_value: str, code: int
) -> None:
# Act
simulation = main_heating_overlay_for(main_heating_value, 0)
# Assert
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == code
def test_high_heat_retention_storage_decodes_to_its_own_code_not_old_storage() -> None:
# Act
simulation = main_heating_overlay_for(
"Electric storage heaters, high heat retention", 0
)
# Assert — HHRSH is SAP Table 4a code 409, NOT old large-volume storage (401)
# the classifier funnelled it into (ADR-0044).
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == 409
def test_high_heat_retention_storage_drags_its_intrinsic_companions() -> None:
# HHRSH has a single intrinsic charge control (Table 4e 2404, 0 C adjustment),
# so — unlike a generic storage heater whose control is unobserved — it must
# NOT drag the conservative manual default (2401, +0.7 C penalty), which would
# under-credit it. It is electric, on an off-peak (Dual) meter (ADR-0044).
simulation = main_heating_overlay_for(
"Electric storage heaters, high heat retention", 0
)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_control == 2404
assert simulation.heating.main_fuel_type == 29
assert simulation.heating.meter_type == "Dual"
# Storage category (7) — consistent with storage code 409, so the SAP 10.2
# Table 12a resolver prices the off-peak storage heating off-peak, not peak.
assert simulation.heating.main_heating_category == 7
@pytest.mark.parametrize(
"main_heating_value",
[
"Electric storage heaters, old",
"Electric storage heaters, slimline",
"Electric storage heaters, convector",
"Electric storage heaters, fan",
],
)
def test_storage_heaters_carry_an_off_peak_meter(main_heating_value: str) -> None:
# Storage heaters run on an Economy 7 (off-peak) tariff by design; setting
# only the heating code while leaving a single-rate meter bills every heating
# kWh at the peak rate and collapses the score (an override-set storage
# dwelling left on an oil donor's single meter scored SAP 13 vs ~50 on
# Economy 7). The overlay carries the off-peak meter, like the HHRSH measure.
simulation = main_heating_overlay_for(main_heating_value, 0)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.meter_type == "Dual"
@pytest.mark.parametrize(
"main_heating_value", ["Gas boiler, combi", "Direct-acting electric"]
)
def test_non_storage_heating_resets_to_a_single_rate_meter(
main_heating_value: str,
) -> None:
# A single-rate system must drag a Single meter, not be left untouched: when
# the landlord switches OFF storage heaters the dwelling's old off-peak
# ("Dual") meter would otherwise bleed through and bill the new gas/direct-
# acting system on an Economy-7 split. Coherence is symmetric — off-peak
# codes synthesise Dual, every other code synthesises Single (ADR-0035).
simulation = main_heating_overlay_for(main_heating_value, 0)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.meter_type == "Single"
@pytest.mark.parametrize(
"main_heating_value",
[
"Electric storage heaters, old",
"Electric storage heaters, slimline",
"Electric storage heaters, convector",
"Electric storage heaters, fan",
],
)
def test_storage_heaters_drag_along_conservative_manual_charge_control(
main_heating_value: str,
) -> None:
# The landlord names the system, not its charge control. Manual charge
# control (Table 4e code 2401, +0.7 C MIT adjustment) is the lowest-SAP
# storage control, so it's the safe assumption that never over-credits.
simulation = main_heating_overlay_for(main_heating_value, 0)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_control == 2401
# ...and the storage category (7), consistent with the storage code, so the
# SAP 10.2 Table 12a resolver prices these off-peak, not at the peak rate.
assert simulation.heating.main_heating_category == 7
@pytest.mark.parametrize(
"main_heating_value",
["Direct-acting electric", "Electric boiler", "Electric CPSU"],
)
def test_electric_boiler_overlays_the_boiler_category(
main_heating_value: str,
) -> None:
# A system-replacing override must stamp the boiler heating category (SAP
# Table 4a Category 2 — codes 191/192 are wet electric boilers). Leaving it
# unset inherits the replaced system's: on portfolio 796, 30 of the first
# 40 live 191/192 overrides carried an inherited category — 6 (community)
# or 4 (heat pump) suppressed the HHRSH pathway entirely, and 7 (storage)
# made the Table 12a resolver bill direct-acting heat 100% at the off-peak
# low rate (ADR-0052, #1444).
# Act
simulation = main_heating_overlay_for(main_heating_value, 0)
# Assert — SAP Table 4a Category 2 (boiler system).
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_category == 2
@pytest.mark.parametrize(
"main_heating_value",
["Direct-acting electric", "Electric boiler", "Electric CPSU"],
)
def test_complete_electric_boiler_overlay_does_not_log_a_companion_gap(
main_heating_value: str, caplog: pytest.LogCaptureFixture
) -> None:
# Electric boilers now resolve a full companion set (category 2 + control
# 2101, ADR-0052), so the overlay must NOT log an incomplete-companion gap
# — guarding that the set stays complete.
# Act
with caplog.at_level(logging.ERROR):
main_heating_overlay_for(main_heating_value, 0)
# Assert
assert "incomplete companion set" not in caplog.text
@pytest.mark.parametrize(
"main_heating_value",
["Direct-acting electric", "Electric boiler", "Electric CPSU"],
)
def test_electric_boiler_drags_the_conservative_group_1_control(
main_heating_value: str,
) -> None:
# The landlord names the system, not its control, so the overlay assumes
# the conservative Table 4e Group 1 default: 2101 ("no time or thermostatic
# control", +0.6 C — the largest Group 1 adjustment, so an unobserved
# control is never over-credited; the boiler mirror of storage 2401 /
# room-heater 2601 / underfloor 2701). Supersedes the old "direct-acting
# drags no control" pin: an unset control is not "no control" — it INHERITS
# the replaced system's (a community 2306 or storage 2401 rode along on
# portfolio 796). Deliberately NOT the gas boilers' modern 2106 — nothing
# in the electric archetype implies a modern install (ADR-0052).
# Act
simulation = main_heating_overlay_for(main_heating_value, 0)
# Assert — SAP Table 4e Group 1 conservative boiler control.
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_control == 2101
@pytest.mark.parametrize(
"main_heating_value", ["Gas boiler, combi", "Gas boiler, regular", "Gas CPSU"]
)
def test_gas_boiler_assumes_full_modern_controls(main_heating_value: str) -> None:
# The landlord names the boiler, not its controls. A gas boiler installed
# under modern Building Regs carries programmer + room thermostat + TRVs
# (SAP Table 4c code 2106), and the overlay already assumes the modern
# condensing efficiency for the boiler — so assuming modern controls is the
# coherent, consistent default (Khalim). It also overwrites any stale storage
# charge control (2401) the dwelling carried before the switch.
simulation = main_heating_overlay_for(main_heating_value, 0)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_control == 2106
@pytest.mark.parametrize(
"main_heating_value", ["Gas boiler, combi", "Gas boiler, regular", "Gas CPSU"]
)
def test_gas_boiler_drags_a_coherent_mains_gas_system(main_heating_value: str) -> None:
# A gas boiler implies a mains-gas connection and a gas main fuel, a gas-
# boiler heating category (Table 4a cat 2), and a fanned room-sealed flue
# (a modern condensing boiler). Setting these on the system overlay makes a
# heating-system-only override self-coherent — it does not depend on a
# separate main_fuel override also being present.
simulation = main_heating_overlay_for(main_heating_value, 0)
assert simulation is not None
assert simulation.heating is not None
heating = simulation.heating
assert heating.gas_connection_available is True
assert heating.main_fuel_type == 26
assert heating.main_heating_category == 2
assert heating.fan_flue_present is True
def test_gas_combi_has_no_hot_water_cylinder() -> None:
# A combi heats hot water instantaneously — there is no cylinder. Elmhurst
# greys out the cylinder choice for a combi (Khalim). The overlay clears the
# cylinder + routes hot water from the main system so a storage dwelling's
# old electric-immersion cylinder doesn't bleed through.
simulation = main_heating_overlay_for("Gas boiler, combi", 0)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.has_hot_water_cylinder is False
assert simulation.heating.water_heating_code == 901
assert simulation.heating.water_heating_fuel == 26
@pytest.mark.parametrize("main_heating_value", ["Gas boiler, regular", "Gas CPSU"])
def test_regular_gas_boiler_keeps_a_hot_water_cylinder(
main_heating_value: str,
) -> None:
# A regular boiler (and a gas CPSU) heats a hot-water cylinder from the main
# system. Elmhurst lets you pick a cylinder for a regular condensing boiler
# (Khalim).
simulation = main_heating_overlay_for(main_heating_value, 0)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.has_hot_water_cylinder is True
assert simulation.heating.water_heating_code == 901
assert simulation.heating.water_heating_fuel == 26
def test_off_peak_archetypes_drag_dual_others_drag_single() -> None:
# Contract (the drag-along guard): the meter is derived from the SAP code via
# the calculator's single off-peak classification, so any archetype whose
# code implies off-peak MUST synthesise a Dual meter and every other code
# MUST synthesise a Single meter — a system switch can never silently leave
# the previous system's meter in place. The one exception is a meter-agnostic
# code (screed underfloor, tariff-ambiguous), which defers to the cert's
# lodged meter (None) rather than assert one (ADR-0046).
for value, code in _MAIN_HEATING_CODES.items():
simulation = main_heating_overlay_for(value, 0)
assert simulation is not None and simulation.heating is not None
if code in _METER_AGNOSTIC_CODES:
expected = None
elif code in _ASSUMED_DUAL_METER_CODES:
expected = "Dual"
else:
expected = "Single"
assert simulation.heating.meter_type == expected, value
@pytest.mark.parametrize(
"main_heating_value",
["Unknown", "", "Community heating"],
)
def test_unresolvable_or_unmodelled_heating_produces_no_overlay(
main_heating_value: str,
) -> None:
# Genuinely unrecognised values (Unknown / empty) and not-yet-modelled
# community heating produce no overlay — the lodged EPC heating stands
# (ADR-0041). Air source heat pumps ARE now modelled (Table 4a 211).
# Act
simulation = main_heating_overlay_for(main_heating_value, 0)
# Assert
assert simulation is None
def test_community_override_keeps_an_observed_group_3_control() -> None:
# A community override on a cert that ALREADY lodges community heating is a
# confirmation, not a system switch — the assessor observed the control
# (e.g. 2306, "charging linked to use, programmer and TRVs", worth ~1-2 SAP
# over the flat-rate default). Stamping the 2313 default over it would
# destroy real information, so the overlay opts into keeping an existing
# Table 4e GROUP 3 control (the heat-network mirror of
# `keep_existing_off_peak_meter`, ADR-0053).
# Arrange — a cert lodging community heating with an observed 2306.
baseline = build_epc()
main = baseline.sap_heating.main_heating_details[0]
main.sap_main_heating_code = 301
main.main_heating_category = 6
main.main_heating_control = 2306
overlay = main_heating_overlay_for("Community heating, boilers", 0)
assert overlay is not None
# Act
result = apply_simulations(baseline, [overlay])
# Assert — the observed usage-linked control survives.
assert result.sap_heating.main_heating_details[0].main_heating_control == 2306
def test_community_override_replaces_a_cross_family_control() -> None:
# When the replaced system was a DIFFERENT family, its control is stale by
# definition — a Group-1 boiler zone control (2110) has no meaning on a
# heat network (two live portfolio-796 dwellings carried exactly that) —
# so the Group 3 default is stamped (ADR-0053).
# Arrange — a cert lodging a gas boiler with zone control.
baseline = build_epc()
main = baseline.sap_heating.main_heating_details[0]
main.sap_main_heating_code = 102
main.main_heating_category = 2
main.main_heating_control = 2110
overlay = main_heating_overlay_for("Community heating, boilers", 0)
assert overlay is not None
# Act
result = apply_simulations(baseline, [overlay])
# Assert — the stale boiler control is replaced by the Group 3 default.
assert result.sap_heating.main_heating_details[0].main_heating_control == 2313
def test_main_heating_override_remaps_the_primary_system_code() -> None:
# Arrange
baseline = build_epc()
overlay = main_heating_overlay_for("Gas boiler, regular", 0)
assert overlay is not None
# Act
result = apply_simulations(baseline, [overlay])
# Assert — the calculator reads the code off main_heating_details[0].
assert result.sap_heating.main_heating_details[0].sap_main_heating_code == 102
def test_gas_boiler_override_onto_a_storage_baseline_leaves_no_stale_fields() -> None:
# Regression for property 728513: a landlord reclassified an electric-storage
# flat as a gas combi via the main_fuel + water_heating + main_heating_system
# overrides. Before the coherent drag-along the override set only the heating
# code + fuel and left the storage system's fields in place — mains_gas False,
# category 7, the 2401 charge control, a Dual meter, an electric-immersion
# cylinder — an incoherent record that gated out the gas-boiler path and made
# the engine read the dwelling as off-gas (offering HHRSH). The override must
# now overwrite ALL of them, regardless of the (undefined) overlay order.
baseline = build_epc()
overlays = [
fuel_overlay_for("mains gas", 0),
water_heating_overlay_for("From main system, mains gas", 0),
main_heating_overlay_for("Gas boiler, combi", 0),
]
assert all(o is not None for o in overlays)
# Act
result = apply_simulations(baseline, [o for o in overlays if o is not None])
# Assert — a fully coherent mains-gas combi, no electric-storage residue.
main = result.sap_heating.main_heating_details[0]
assert main.sap_main_heating_code == 104
assert main.main_fuel_type == 26
assert main.main_heating_category == 2
assert main.main_heating_control == 2106
assert result.sap_energy_source.gas_connection_available is True
assert result.sap_energy_source.meter_type == "Single"
assert result.has_hot_water_cylinder is False
assert result.sap_heating.water_heating_code == 901
assert result.sap_heating.water_heating_fuel == 26
def test_the_three_heating_overrides_compose_without_conflict() -> None:
# Arrange — main_fuel, water_heating and main_heating_system all fold onto one
# HeatingOverlay surface but set DISJOINT fields, so they compose (the
# field-disjoint design that makes precedence moot for these three).
baseline = build_epc()
overlays = [
fuel_overlay_for("electricity", 0),
water_heating_overlay_for("Electric immersion, electricity", 0),
main_heating_overlay_for("Electric storage heaters, fan", 0),
]
assert all(o is not None for o in overlays)
# Act
result = apply_simulations(baseline, [o for o in overlays if o is not None])
# Assert — each override landed on its own field.
main = result.sap_heating.main_heating_details[0]
assert main.main_fuel_type == 29
assert main.sap_main_heating_code == 404
assert result.sap_heating.water_heating_code == 903
assert result.sap_heating.water_heating_fuel == 29
def test_room_heaters_preserve_an_existing_more_off_peak_cert_meter() -> None:
# The overlay's assumed Dual (7-hour E7) meter is a coherent *default* for a
# single/unknown-meter dwelling — it must NOT downgrade a cert that already
# lodges a more-off-peak meter (here a 24-hour all-low tariff, code "4").
# Clobbering it to E7 would bill the heating on a high/low split it doesn't
# have, under-rating the dwelling.
baseline = build_epc()
baseline.sap_energy_source.meter_type = "4" # 24-hour tariff
overlay = main_heating_overlay_for("Electric room heaters", 0)
assert overlay is not None
result = apply_simulations(baseline, [overlay])
assert result.sap_energy_source.meter_type == "4"
def test_room_heaters_set_dual_when_the_cert_meter_is_single() -> None:
# The flip side: a single-rate dwelling DOES get the assumed Dual meter —
# off-peak heating can't be billed on a single-rate meter (ADR-0035 drag).
baseline = build_epc()
baseline.sap_energy_source.meter_type = "Single"
overlay = main_heating_overlay_for("Electric room heaters", 0)
assert overlay is not None
result = apply_simulations(baseline, [overlay])
assert result.sap_energy_source.meter_type == "Dual"
def test_electric_room_heaters_member_decodes_to_the_room_heater_code() -> None:
# Arrange — the canonical landlord archetype for direct-acting room heaters
member = MainHeatingSystemType.ELECTRIC_ROOM_HEATERS
# Act
simulation = main_heating_overlay_for(member.value, 0)
# Assert — member value stays in lock-step with the overlay (code 691)
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == 691
@pytest.mark.parametrize(
"member",
[m for m in MainHeatingSystemType if m is not MainHeatingSystemType.UNKNOWN],
)
def test_every_resolvable_main_heating_value_decodes(
member: MainHeatingSystemType,
) -> None:
# Act
simulation = main_heating_overlay_for(member.value, 0)
# Assert
assert simulation is not None
def test_solid_fuel_room_heater_decodes_to_the_closed_room_heater_code() -> None:
# A landlord-named solid-fuel room heater (e.g. a closed stove) is a
# recognised archetype, not a gas wet system — it must decode to its SAP
# Table 4a code (633, closed solid-fuel room heater), not overflow into the
# nearest wrong archetype the way the under-populated taxonomy did, sending
# "solid fuel room heaters: closed room heater" to Gas CPSU (ADR-0041).
# Act
simulation = main_heating_overlay_for("Solid fuel room heater, closed", 0)
# Assert — SAP Table 4a code 633 (closed solid-fuel room heater).
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == 633
def test_solid_fuel_room_heater_drags_its_coherent_room_heater_companions() -> None:
# The landlord names the system, not its category/control/meter. A solid-fuel
# room heater is a room-heater system (Table 4a category 10) on a single-rate
# meter (not off-peak storage), under the conservative room-heater control
# real certs lodge (Table 4e Group 6 code 2601 — "no thermostatic control",
# the lowest-SAP room-heater control, so it never over-credits an unobserved
# control, mirroring the storage manual-charge default). ADR-0035.
# Act
simulation = main_heating_overlay_for("Solid fuel room heater, closed", 0)
# Assert
assert simulation is not None
assert simulation.heating is not None
heating = simulation.heating
assert heating.main_heating_category == 10
assert heating.main_heating_control == 2601
assert heating.meter_type == "Single"
def test_electric_room_heaters_drag_their_natural_electricity_fuel() -> None:
# A landlord names the system; an electric room heater's natural fuel is
# unambiguously electricity (RdSAP main_fuel code 29). The overlay drags it so
# a system-only override is self-coherent even on a cert that lodged a
# different fuel — a later `main_fuel` override still wins (last-wins
# composition), and a contradicting fuel is logged, not silently kept
# (ADR-0041 natural-fuel coherence).
# Act
simulation = main_heating_overlay_for("Electric room heaters", 0)
# Assert
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_fuel_type == 29
def test_solid_fuel_room_heater_defaults_to_house_coal_as_its_natural_fuel() -> None:
# Solid fuel is fuel-ambiguous (coal / anthracite / smokeless / dual fuel /
# wood logs / pellets), but the system must still self-cohere when no
# main_fuel override is given. Default to house coal (RdSAP main_fuel code
# 33), the most common solid fuel; a main_fuel override naming a specific
# solid fuel still wins by last-wins composition (ADR-0041).
# Act
simulation = main_heating_overlay_for("Solid fuel room heater, closed", 0)
# Assert
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_fuel_type == 33
def test_air_source_heat_pump_decodes_to_the_default_ashp_code() -> None:
# A landlord names "air source heat pump" without a PCDB model. It is
# modellable via the SAP Table 4a default ASHP code (211, "flow temp in other
# cases", default SPF 2.30) — no main_heating_index_number needed — so it must
# decode to 211, not produce no overlay / fall to Unknown (ADR-0041).
# Act
simulation = main_heating_overlay_for("Air source heat pump", 0)
# Assert — SAP Table 4a code 211 (default air-source heat pump).
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == 211
def test_air_source_heat_pump_drags_its_coherent_companions() -> None:
# A heat pump is unambiguously electric (natural fuel 29) and SAP Table 4a
# category 4. Unlike storage/CPSU it does NOT imply an off-peak tariff (SAP
# §12 Rule 3 is conditional, not forcing), so the coherent default meter is
# single-rate — forcing Dual would assume an off-peak split it may not have
# and mis-bill it. The overlay drags these code-derived companions so a
# system-only override is self-coherent (ADR-0035 / ADR-0041).
# Act
simulation = main_heating_overlay_for("Air source heat pump", 0)
# Assert
assert simulation is not None
assert simulation.heating is not None
heating = simulation.heating
assert heating.main_heating_category == 4
assert heating.main_fuel_type == 29
assert heating.meter_type == "Single"
def test_community_boilers_decode_to_the_heat_network_boiler_code() -> None:
# A community/heat-network scheme driven by boilers is SAP Table 4a code 301
# (the calculator derives the heat-source efficiency + DLF from it). It must
# decode to 301, not the Gas CPSU (120) the under-populated taxonomy forced —
# a single-dwelling gas wet boiler is the wrong picture for a heat network
# (ADR-0041). A generic "Community heating" with no named source stays None.
# Act
simulation = main_heating_overlay_for("Community heating, boilers", 0)
# Assert — SAP Table 4a code 301 (boiler-driven community heating).
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == 301
def test_community_boilers_drag_heat_network_category_and_a_community_gas_fuel() -> (
None
):
# A community boiler scheme is SAP main_heating_category 6 (heat network), so
# the calculator treats it as a heat network (cert_to_inputs `_is_heat_network`
# checks code OR category 6). Its natural fuel is mains gas (community) — RdSAP
# main_fuel code 20, the dominant fuel real community-boiler certs lodge. A
# specific main_fuel override (e.g. biomass community) still wins (ADR-0041).
# Act
simulation = main_heating_overlay_for("Community heating, boilers", 0)
# Assert
assert simulation is not None
assert simulation.heating is not None
heating = simulation.heating
assert heating.main_heating_category == 6
assert heating.main_fuel_type == 20
def test_community_chp_and_boilers_decode_to_their_heat_network_code() -> None:
# A community scheme with CHP + boilers is SAP Table 4a code 302, still a heat
# network (category 6) on community mains gas (20). Real audit data: 10
# properties carry this, today mis-bucketed to Gas CPSU (ADR-0041).
# Act
simulation = main_heating_overlay_for("Community heating, CHP and boilers", 0)
# Assert
assert simulation is not None
assert simulation.heating is not None
heating = simulation.heating
assert heating.sap_main_heating_code == 302
assert heating.main_heating_category == 6
assert heating.main_fuel_type == 20
def test_oil_room_heater_decodes_to_the_post_2000_code() -> None:
# A modern standalone oil room heater is SAP Table 4a code 623 ("Oil room
# heater, 2000 or later", no boiler). It must decode to 623, not the Gas CPSU
# the under-populated taxonomy forced (ADR-0041).
# Act
simulation = main_heating_overlay_for("Oil room heater, 2000 or later", 0)
# Assert — SAP Table 4a code 623.
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == 623
def test_oil_room_heater_drags_its_coherent_room_heater_companions() -> None:
# An oil room heater is a room-heater system (category 10) on a single-rate
# meter, under the conservative room-heater control (2601), with its natural
# fuel heating oil (RdSAP main_fuel 28). The overlay drags these so a
# system-only override is self-coherent (ADR-0035 / ADR-0041).
# Act
simulation = main_heating_overlay_for("Oil room heater, 2000 or later", 0)
# Assert
assert simulation is not None
assert simulation.heating is not None
heating = simulation.heating
assert heating.main_heating_category == 10
assert heating.main_heating_control == 2601
assert heating.main_fuel_type == 28
assert heating.meter_type == "Single"
@pytest.mark.parametrize(
("value", "code"),
[
("Gas room heater, condensing fire", 611),
("Gas room heater, decorative fuel-effect", 612),
("Gas room heater, flush live-effect", 605),
("Gas room heater, open flue 1980 or later", 603),
("Gas room heater, open flue pre-1980", 601),
],
)
def test_gas_room_heater_variants_decode_to_their_sap_codes(
value: str, code: int
) -> None:
# Gas room heaters span a wide efficiency range (decorative 0.20 -> condensing
# 0.85), so each catalogue variant maps to its own SAP Table 4a code rather
# than collapsing to one representative — which would over-credit a decorative
# fire and under-credit a condensing one. Today they mis-bucket to "Gas
# boiler, regular" (ADR-0041).
# Act
simulation = main_heating_overlay_for(value, 0)
# Assert
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.sap_main_heating_code == code
def test_gas_room_heater_drags_its_coherent_companions() -> None:
# A gas room heater is a room-heater system (category 10) on a single-rate
# meter, under the conservative room-heater control (2601). Its natural fuel
# is mains gas (26) — an LPG dwelling is refined by a main_fuel override
# (the overlay can't see the mains connection) (ADR-0041).
# Act
simulation = main_heating_overlay_for("Gas room heater, condensing fire", 0)
# Assert
assert simulation is not None
assert simulation.heating is not None
heating = simulation.heating
assert heating.main_heating_category == 10
assert heating.main_heating_control == 2601
assert heating.main_fuel_type == 26
assert heating.meter_type == "Single"