Model/tests/domain/property_baseline
Khalim Conn-Kowlessar bf240e3315 ASHP sizing targets the Appendix-N efficiency peak (realistic installed pump) 🟩
Sizing selects the aroTHERM plus rung nearest PSR ~0.8 (0.8 x design heat
loss) — the Appendix-N efficiency peak, reproducing the pump a real
installer fits — rather than the MCS PSR>=1.0 capacity target, which
oversizes. Validated against the relodged Elmhurst ASHP cert (delta 0
held at the 5 kW Vaillant); the two self-snapshot pins re-pin to their
correctly-sized larger pumps, and the orchestrator/harness thread the
calculator's design heat loss so production sizes to the dwelling. Manual
SapResult test stubs carry the new design_heat_loss_kw field.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 11:02:13 +00:00
..
__init__.py refactor(property-baseline): rename baseline → property_baseline aggregate (PR #1139 review) 2026-06-01 14:54:59 +00:00
test_calculator_rebaseliner.py ASHP sizing targets the Appendix-N efficiency peak (realistic installed pump) 🟩 2026-07-03 11:02:13 +00:00
test_performance.py refactor(property-baseline): rename baseline → property_baseline aggregate (PR #1139 review) 2026-06-01 14:54:59 +00:00
test_portfolio_796_override_rebaseline.py test: portfolio-796 override-rebaseline regression (the 7 properties) 🟩 2026-06-26 19:22:32 +00:00
test_rebaseliner.py feat(baseline): Rebaseliner returns RebaselineResult carrying the SapResult 2026-06-02 18:37:13 +00:00