Model/backend/documents_parser
Khalim Conn-Kowlessar 23e35da614 Slice 101c: HP cert 0380 — Table 4f cat-4 pumps/fans = 0
SAP 10.2 Table 4f lists annual pumps + fans electricity consumption
by main heating category. The cascade's
`_PUMPS_FANS_KWH_BY_MAIN_CATEGORY` only had cat-2 (gas-fired
boilers, 160 kWh = 115 pump + 45 flue fan) — HP certs (cat 4) fell
through to the 130 kWh/yr DEFAULT.

Heat pumps have NO additional pumps/fans contribution per Table 4f:
the HP system's circulation pump + fans are already incorporated
into the seasonal COP. Worksheet line (249) "Pumps, fans and
electric keep-hot" shows 0.0000 kWh for cert 0380 (ASHP).

Added `4: 0.0`. Effect on cert 0380 API path: pumps_fans cost
£17.15 → £0.00 (matches worksheet); total cost £171.36 → £154.21
(worksheet £206.75; remaining Δ -£52 is dominated by the hot-water
cascade gap which is the next slice — cylinder storage + primary
loss + HP HW COP + separate electric shower line all need work).

No golden cert residual shifts (cohort certs are all gas boilers).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:45 +00:00
..
handler address JTK review comments 2026-04-20 15:11:17 +00:00
tests Slice 101c: HP cert 0380 — Table 4f cat-4 pumps/fans = 0 2026-06-01 16:28:45 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
db_writer.py include updating epc_property_data to pashub to ara workflow 2026-04-29 09:55:14 +00:00
elmhurst_extractor.py Slice 99d: surface PV array from Elmhurst Summary §19.0 2026-06-01 16:28:45 +00:00
extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
local_runner.py update local runner to work for elmhurst 2026-04-24 14:01:36 +00:00
parser.py load ecmk site notes to db 2026-04-29 11:20:47 +00:00
pdf.py update local runner to work for elmhurst 2026-04-24 14:01:36 +00:00