Model/tests/domain/modelling/fixtures
Khalim Conn-Kowlessar f31d5bcff9 feat(modelling): typed SolarPotential projection over Google buildingInsights
Slice 2 of the Solar PV Recommendation Generator (ADR-0026). Adds the
strictly-typed `SolarPotential` domain projection over the raw Google Solar
`buildingInsights` JSON that Ingestion persists (SolarRepository): the
`solarPanelConfigs` ladder, each rung broken into its roof segments with
Google's continuous azimuth/tilt mapped to the SAP octant
(`azimuth_to_sap_octant`, 0°=N clockwise → 1=N..8=NW, matching the
calculator's ORIENTATION_BY_SAP10_CODE) and RdSAP §11.1 pitch code
(`pitch_to_sap_code`, snap to {0→1,30→2,45→3,60→4,90→5}).

Pinned against the real London buildingInsights example (mirrored into
fixtures from the user-provided RTF): 400 W panels, maxArrayPanelsCount 49,
46-rung ladder, per-segment SE/NW/NE/SW octants at ~32° → pitch code 2.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 09:55:55 +00:00
..
ashp_from_gas_boiler_001431_before.pdf test(modelling): ASHP before/after cascade pin (001431) at 1e-4 2026-06-06 17:01:40 +00:00
ashp_from_gas_boiler_instant_hw_001431_before.pdf test(modelling): ASHP pin from a gas boiler with instantaneous HW + fuel tripwire 2026-06-06 17:40:25 +00:00
ashp_from_system_boiler_with_cylinder_001431_after.pdf test(modelling): finalize Vaillant ASHP swap on the cascade pins 2026-06-06 21:33:09 +00:00
ashp_from_system_boiler_with_cylinder_001431_before.pdf test(modelling): ASHP from a system gas boiler with an existing cylinder 2026-06-06 18:20:58 +00:00
cavity_wall_001431_after.pdf test(modelling): Elmhurst before/after cascade pin for cavity wall (#1154) 2026-06-03 09:36:53 +00:00
cavity_wall_001431_before.pdf test(modelling): Elmhurst before/after cascade pin for cavity wall (#1154) 2026-06-03 09:36:53 +00:00
double_glazing_001431_after.pdf test(fixtures): add glazing before/after certs (001431) for the pin slices 2026-06-05 07:54:43 +00:00
double_glazing_001431_before.pdf test(fixtures): add glazing before/after certs (001431) for the pin slices 2026-06-05 07:54:43 +00:00
flat_roof_001431_after.pdf feat(modelling): roof dispatcher insulates a flat roof 2026-06-04 21:16:00 +00:00
flat_roof_001431_before.pdf feat(modelling): roof dispatcher insulates a flat roof 2026-06-04 21:16:00 +00:00
google_building_insights_001431.json feat(modelling): typed SolarPotential projection over Google buildingInsights 2026-06-08 09:55:55 +00:00
hhr_storage_001431_after.pdf test(modelling): HHRSH before/after cascade pins (001431) at 1e-4 2026-06-05 19:09:23 +00:00
hhr_storage_from_electric_storage_001431_before.pdf test(modelling): HHRSH before/after cascade pins (001431) at 1e-4 2026-06-05 19:09:23 +00:00
hhr_storage_from_no_system_001431_before.pdf test(modelling): HHRSH before/after cascade pins (001431) at 1e-4 2026-06-05 19:09:23 +00:00
loft_001431_after.pdf feat(modelling): loft overlay 270→300 mm + Elmhurst cascade pin (#1158) 2026-06-03 09:39:21 +00:00
loft_001431_before.pdf feat(modelling): loft overlay 270→300 mm + Elmhurst cascade pin (#1158) 2026-06-03 09:39:21 +00:00
loft_thatched_001431_after.pdf feat(modelling): fold loft into the roof dispatcher; thatch routes to loft 2026-06-04 21:12:01 +00:00
loft_thatched_001431_before.pdf feat(modelling): fold loft into the roof dispatcher; thatch routes to loft 2026-06-04 21:12:01 +00:00
low_energy_lighting_some_leds_001431_after.pdf test(modelling): lighting before/after cascade pins (001431) at 1e-4 2026-06-05 12:27:36 +00:00
low_energy_lighting_some_leds_001431_before.pdf test(modelling): lighting before/after cascade pins (001431) at 1e-4 2026-06-05 12:27:36 +00:00
low_energy_lighting_zero_leds_001431_after.pdf test(modelling): lighting before/after cascade pins (001431) at 1e-4 2026-06-05 12:27:36 +00:00
low_energy_lighting_zero_leds_001431_before.pdf test(modelling): lighting before/after cascade pins (001431) at 1e-4 2026-06-05 12:27:36 +00:00
secondary_glazing_001431_after.pdf test(fixtures): add glazing before/after certs (001431) for the pin slices 2026-06-05 07:54:43 +00:00
secondary_glazing_001431_before.pdf test(fixtures): add glazing before/after certs (001431) for the pin slices 2026-06-05 07:54:43 +00:00
sloping_ceiling_001431_after.pdf feat(modelling): recommend_roof_insulation insulates a sloping ceiling 2026-06-04 21:02:06 +00:00
sloping_ceiling_001431_before.pdf feat(modelling): recommend_roof_insulation insulates a sloping ceiling 2026-06-04 21:02:06 +00:00
solid_brick_ewi_001431_after.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_brick_ewi_001431_before.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_brick_iwi_001431_after.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_brick_iwi_001431_before.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_floor_001431_after.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00
solid_floor_001431_before.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00
suspended_floor_001431_after.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00
suspended_floor_001431_before.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00
system_built_ewi_001431_after.pdf feat(modelling): system-built walls take EWI+IWI (blocked on basement-code fix) 2026-06-04 18:26:08 +00:00
system_built_ewi_001431_before.pdf feat(modelling): system-built walls take EWI+IWI (blocked on basement-code fix) 2026-06-04 18:26:08 +00:00
system_built_iwi_001431_after.pdf feat(modelling): system-built walls take EWI+IWI (blocked on basement-code fix) 2026-06-04 18:26:08 +00:00
system_built_iwi_001431_before.pdf feat(modelling): system-built walls take EWI+IWI (blocked on basement-code fix) 2026-06-04 18:26:08 +00:00
timber_frame_iwi_001431_after.pdf feat(modelling): solid-wall generator offers IWI-only for timber frame 2026-06-04 15:33:46 +00:00
timber_frame_iwi_001431_before.pdf feat(modelling): solid-wall generator offers IWI-only for timber frame 2026-06-04 15:33:46 +00:00