Model/tests/domain/modelling/fixtures
Khalim Conn-Kowlessar 3d738bd4c6 test(fixtures): add glazing before/after certs (001431) for the pin slices
The double_glazing / secondary_glazing Elmhurst before→after Summaries the
glazing generator's cascade pins will use (ADR-0022). NB: these don't parse
yet — cert 001431 lodges several unmapped glazing labels ("Secondary glazing",
"Secondary glazing - Normal emissivity", "Triple pre 2002", truncated
"Double…"/"Triple…" variants) that the mapper must cover first.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-05 07:54:43 +00:00
..
cavity_wall_001431_after.pdf test(modelling): Elmhurst before/after cascade pin for cavity wall (#1154) 2026-06-03 09:36:53 +00:00
cavity_wall_001431_before.pdf test(modelling): Elmhurst before/after cascade pin for cavity wall (#1154) 2026-06-03 09:36:53 +00:00
double_glazing_001431_after.pdf test(fixtures): add glazing before/after certs (001431) for the pin slices 2026-06-05 07:54:43 +00:00
double_glazing_001431_before.pdf test(fixtures): add glazing before/after certs (001431) for the pin slices 2026-06-05 07:54:43 +00:00
flat_roof_001431_after.pdf feat(modelling): roof dispatcher insulates a flat roof 2026-06-04 21:16:00 +00:00
flat_roof_001431_before.pdf feat(modelling): roof dispatcher insulates a flat roof 2026-06-04 21:16:00 +00:00
loft_001431_after.pdf feat(modelling): loft overlay 270→300 mm + Elmhurst cascade pin (#1158) 2026-06-03 09:39:21 +00:00
loft_001431_before.pdf feat(modelling): loft overlay 270→300 mm + Elmhurst cascade pin (#1158) 2026-06-03 09:39:21 +00:00
loft_thatched_001431_after.pdf feat(modelling): fold loft into the roof dispatcher; thatch routes to loft 2026-06-04 21:12:01 +00:00
loft_thatched_001431_before.pdf feat(modelling): fold loft into the roof dispatcher; thatch routes to loft 2026-06-04 21:12:01 +00:00
secondary_glazing_001431_after.pdf test(fixtures): add glazing before/after certs (001431) for the pin slices 2026-06-05 07:54:43 +00:00
secondary_glazing_001431_before.pdf test(fixtures): add glazing before/after certs (001431) for the pin slices 2026-06-05 07:54:43 +00:00
sloping_ceiling_001431_after.pdf feat(modelling): recommend_roof_insulation insulates a sloping ceiling 2026-06-04 21:02:06 +00:00
sloping_ceiling_001431_before.pdf feat(modelling): recommend_roof_insulation insulates a sloping ceiling 2026-06-04 21:02:06 +00:00
solid_brick_ewi_001431_after.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_brick_ewi_001431_before.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_brick_iwi_001431_after.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_brick_iwi_001431_before.pdf feat(modelling): overlay models solid-wall insulation (IWI/EWI), pinned 2026-06-04 15:11:26 +00:00
solid_floor_001431_after.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00
solid_floor_001431_before.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00
suspended_floor_001431_after.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00
suspended_floor_001431_before.pdf feat(modelling): floor insulation-type overlay field + cascade pins (#1159) 2026-06-03 09:41:54 +00:00
system_built_ewi_001431_after.pdf feat(modelling): system-built walls take EWI+IWI (blocked on basement-code fix) 2026-06-04 18:26:08 +00:00
system_built_ewi_001431_before.pdf feat(modelling): system-built walls take EWI+IWI (blocked on basement-code fix) 2026-06-04 18:26:08 +00:00
system_built_iwi_001431_after.pdf feat(modelling): system-built walls take EWI+IWI (blocked on basement-code fix) 2026-06-04 18:26:08 +00:00
system_built_iwi_001431_before.pdf feat(modelling): system-built walls take EWI+IWI (blocked on basement-code fix) 2026-06-04 18:26:08 +00:00
timber_frame_iwi_001431_after.pdf feat(modelling): solid-wall generator offers IWI-only for timber frame 2026-06-04 15:33:46 +00:00
timber_frame_iwi_001431_before.pdf feat(modelling): solid-wall generator offers IWI-only for timber frame 2026-06-04 15:33:46 +00:00